Available powers: 15kW | 20kW | 30kW | 40kW | 50kW | 75kW
Z
Fuel: Pellets
Z
Certificates: EcoDesign | 5 class | TÜV
Z
Energy class: A +

General information

Combine economy with efficiency!

The SEG BIO boiler uses reliable technological and design solutions that make it an exceptionally effective and proven source of heat. The boiler is adapted to the efficient combustion of class C wood pallet in accordance with the PN EN 303-5: 2012 standard. It is equipped with a self-cleaning burner. Pellet lighter cooperating with the RTC clock, lighting up and extinguishing the boiler according to the schedule, reducing the number of activities to be performed on the boiler to almost zero.

Technology and security

Z

Heat exchanger

Horizontal and vertical convection channels | regimental
Efficient design adapted to quickly clean the exchanger on the front and top. The design of the boiler exchanger ensures high heat removal from the furnace.
Z

Flue outlet

At the back of the boiler
The structure of the boiler has been designed in such a way that the flue outlet is at the rear. The use of such a solution in a central heating boiler allows the flue to be directly led out to the chimney.
Z

Automatic feeder

The PLATINUM controller, on the basis of information received from sensors, determines the demand for fuel and doses it the right amount. The process of fuel combustion itself is therefore very economical, ecological and does not require additional service on the part of the user.
Z

Swirlers

The swirlers installed in the convection channels effectively reduce the speed of the exhaust gas outlet while maintaining high heat reception by the water cry.
Z

Limit switch

For your safety, the boiler is equipped with a limit switch. The end protection system is located in the boiler door and the tank flap. Each opening of the door or the flap causes the burner and other elements of the boiler to stop working automatically until they are closed again.
Z

Firefighter

It protects the fuel in the boiler container against ignition.

Connectivity and functionality

Simple and intuitive boiler control

Adjust the boiler operation and room temperature to your individual needs. The PLATINUM controller is programmed in such a way as to automate all processes related to the heating of your home. The owner specifies the temperature he wants to have in the apartment, and the controller will optimize combustion in this respect. Entering the advanced driver settings, you can personalize each parameter. It all depends on the preferences of the user and household members!

Key Features:

E
Pump (DHW, C.H.1, C.O.2, circulation, additional)
E
Two CH.1 and CH.2 mixing circuits with a room thermostat
E
RTC clock with weekly timer
E
Weather control
E
Winter / summer operation mode
E

FuzzyLogic & PID

Z

Optional accessories

  • Lambda probe
  • ecoNET 300 internet module
  • Platinum B module (buffer operation control, additional two heating circuits, 2x pump, 2x mixer, 2x thermostat)
  • Platinum C module (two additional heating circuits, 2x pump, 2x mixer, 2x thermostat)
Z

Optional accessories

  • PLATINUM TOUCH room thermostat (touchscreen, wired)
  • PLATINUM TOUCH x40 room thermostat (analog, wireless)
  • PLATINUM TOUCH x80 room thermostat (touch, wireless)

Gutter Burner

Gutter burner – for pellets

These are one of the most popular pellet burners on the market. The burner is equipped with an automatic ceramic pellet igniter, which allows it to be quickly ignited and extinguished. The design of the burner allows you to quickly reach a high temperature of the boiler. All functions of firing up the furnace and fuel dosage can be set in accordance with the current needs of the user.

Z

Fuel: Pellets

Ecological fuel such as pellets, also known as biomass, is produced by pressing wood waste such as sawdust or shavings. This completely natural fuel turns into biodegradable ash after burning.
Z

Ceramic pellet lighter

Forget about manual boiler lighting. One click is enough and the automatic ceramic igniter ignites the fuel fed to the burner. Automatic igniter in conjunction with the RTC clock allows you to program the entire week of operation of the device. The device operation clock can be set separately for SUMMER and WINTER mode.

Technical data of the boiler

PARAMETERS S.I. UNIT SEG BIO 15
Nominal heat output[kW]15
Range of boiler power[kW]4.5-15
Area that can be heated *[m2]45-225
Heating area[m2]2,1
Water capacity[L]60
Maximum working pressure[bar]3
Maximum operating temperature[°C]80
Test pressure[bar]4.5
Fuel hopper capacity[L]190
Fuel tank capacity[kg]114
Fuel[-]pellets Φ6-8mm
Electrical connection[-]5A; ~ 230V; 50Hz
Electric power consumption[W]300
Temperature controller setting range[° C]60-80 (1°C steps)
Chimney draft required[Pa]20
Boiler weight[kg]396

* A new building with very good thermal insulation was adopted for the calculations.

PARAMETERS S.I. UNIT SEG BIO 20
Nominal heat output[kW]20
Range of boiler power[kW]6-20
Area that can be heated *[m2]60-300
Heating area[m2]2.54
Water capacity[L]68
Maximum working pressure[bar]3
Maximum operating temperature[°C]80
Test pressure[bar]4.5
Fuel tank capacity[L]290
Fuel tank capacity[kg]174
Fuel[-]pellets Φ6-8mm
Electrical connection[-]5A; ~ 230V; 50Hz
Electric power consumption[W]300
Temperature controller setting range[°C]60-80 (1°C steps)
Chimney draft required[Pa]23
Boiler weight[kg]474

* A new building with very good thermal insulation was adopted for the calculations.

PARAMETERS S.I. UNIT SEG BIO 30
Nominal heat output[kW]30
Range of boiler power[kW]9-30
Area that can be heated *[m2]90-450
Heating area[m2]2.85
Water capacity[L]73
Maximum working pressure[bar]3
Maximum operating temperature[°C]80
Test pressure[bar]4.5
Fuel tank capacity[L]350
Fuel tank capacity[kg]210
Fuel[-]pellets Φ6-8mm
Electrical connection[-]5A; ~ 230V; 50Hz
Electric power consumption[W]300
Temperature controller setting range[°C]60-80 (1°C steps)
Chimney draft required[Pa]23
Boiler weight[kg]510

* A new building with very good thermal insulation was adopted for the calculations.

PARAMETERS S.I. UNIT SEG BIO 40
Nominal heat output[kW]40
Range of boiler power[kW]12-40
Area that can be heated *[m2]120-600
Heating area[m2]3.11
Water capacity[L]95
Maximum working pressure[bar]3
Maximum operating temperature[°C]80
Test pressure[bar]4.5
Fuel tank capacity[L]350
Fuel tank capacity[kg]210
Fuel[-]pellets Φ6-8mm
Electrical connection[-]5A; ~ 230V; 50Hz
Electric power consumption[W]300
Temperature controller setting range[°C]60-80 (1°C steps)
Chimney draft required[Pa]35
Boiler weight[kg]530

* A new building with very good thermal insulation was adopted for the calculations.

PARAMETERS S.I. UNIT SEG BIO 50
Nominal heat output[kW]50
Range of boiler power[kW]15-50
Area that can be heated *[m2]150-750
Heating area[m2]5.41
Water capacity[L]120
Maximum working pressure[bar]3
Maximum operating temperature[°C]80
Test pressure[bar]4.5
Fuel tank capacity[L]400
Fuel tank capacity[kg]240
Fuel[-]pellets Φ6-8mm
Electrical connection[-]5A; ~ 230V; 50Hz
Electric power consumption[W]400
Temperature controller setting range[°C]60-80 (1°C steps)
Chimney draft required[Pa]38
Boiler weight[kg]725

* A new building with very good thermal insulation was adopted for the calculations.

PARAMETERS S.I. UNIT SEG BIO 75
Nominal heat output[kW]75
Range of boiler power[kW]22.5-75
Area that can be heated *[m2]225-1125
Heating area[m2]6.75
Water capacity[L]173
Maximum working pressure[bar]3
Maximum operating temperature[°C]80
Test pressure[bar]4.5
Fuel tank capacity[L]520
Fuel tank capacity[kg]312
Fuel[-]pellets Φ6-8mm
Electrical connection[-]5A; ~ 230V; 50Hz
Electric power consumption[W]400
Temperature controller setting range[°C]60-80 (1°C steps)
Chimney draft required[Pa]40
Boiler weight[kg]855

* A new building with very good thermal insulation was adopted for the calculations.

CERTIFICATES, CLASS, BOILER EMISSIONS

PARAMETERS S.I. UNIT SEG BIO 15
Ecodesign[-]yes
Boiler class[-]5
Energy class[-]A +
Particulate emission[mg / m3]33
PARAMETERS S.I. UNIT SEG BIO 20
Ecodesign[-]yes
Boiler class[-]5
Energy class[-]A +
Particulate emission[mg / m3]36
PARAMETERS S.I. UNIT SEG BIO 30
Ecodesign[-]yes
Boiler class[-]5
Energy class[-]A +
Particulate emission[mg / m3]33
PARAMETERS S.I. UNIT SEG BIO 40
Ecodesign[-]yes
Boiler class[-]5
Energy class[-]A +
Particulate emission[mg / m3]30
PARAMETERS S.I. UNIT SEG BIO 50
Ecodesign[-]yes
Boiler class[-]5
Energy class[-]A +
Particulate emission[mg / m3]31
PARAMETERS S.I. UNIT SEG BIO 75
Ecodesign[-]yes
Boiler class[-]5
Energy class[-]A +
Particulate emission[mg / m3]26

Boiler dimensions

DIMENSION S.I. UNIT SEG BIO 15
A[mm]1256
B1[mm]535
B2[mm]680
C1[mm]1160
C2[mm]1130
D1[mm]870
D2[mm]705
E[mm]707
F1[mm]910
F2[mm]213
F3[mm]213
F4[mm]350
G1[mm]180
G2[cal]1 1/2
G3[cal]1 1/2
G4[cal]3/4
H[mm]30
DIMENSION S.I. UNIT SEG BIO 20
A[mm]1256
B1[mm]535
B2[mm]680
C1[mm]1355
C2[mm]1325
D1[mm]905
D2[mm]745
E[mm]720
F1[mm]1105
F2[mm]247
F3[mm]207
F4[mm]360
G1[mm]180
G2[cal]1 1/2
G3[cal]1 1/2
G4[cal]3/4
H[mm]30
DIMENSION S.I. UNIT SEG BIO 30
A[mm]1256
B1[mm]535
B2[mm]680
C1[mm]1415
C2[mm]1385
D1[mm]955
D2[mm]795
E[mm]776
F1[mm]1160
F2[mm]245
F3[mm]205
F4[mm]410
G1[mm]180
G2[cal]1 1/2
G3[cal]1 1/2
G4[cal]3/4
H[mm]30
DIMENSION S.I. UNIT SEG BIO 40
A[mm]1306
B1[mm]585
B2[mm]680
C1[mm]1415
C2[mm]1385
D1[mm]955
D2[mm]795
E[mm]766
F1[mm]1160
F2[mm]245
F3[mm]205
F4[mm]410
G1[mm]180
G2[cal]1 1/2
G3[cal]1 1/2
G4[cal]3/4
H[mm]30
DIMENSION S.I. UNIT SEG BIO 50
A[mm]1406
B1[mm]682
B2[mm]680
C1[mm]1484
C2[mm]1454
D1[mm]1218
D2[mm]1003
E[mm]850
F1[mm]1110
F2[mm]337
F3[mm]190
F4[mm]535
G1[mm]220
G2[cal]1 1/2
G3[cal]1 1/2
G4[cal]3/4
H[mm]30
DIMENSION S.I. UNIT SEG BIO 75
A[mm]1505
B1[mm]793
B2[mm]680
C1[mm]1520
C2[mm]1490
D1[mm]1413
D2[mm]1175
E[mm]1075
F1[mm]1115
F2[mm]350
F3[mm]175
F4[mm]350
G1[mm]220
G2[cal]1 1/2
G3[cal]1 1/2
G4[cal]3/4
H[mm]30

Boiler documentation

Z

DTR statement

Technical and operational documentation for the SEG BIO boiler

Z

Driver manual

PLATINUM driver manual

Z

Energy label

A + energy class

Z

Product sheet

According to EU Regulation 2015/1187 supplementing Directive 2009/125 / EC of the European Parliament and of the Council

Z

EcoDesign certificate

The boiler complies with the requirements of the EcoDesign standard

Z

Class 5 Certificate

The boiler complies with the requirements of PN-EN 303-5: 2012

Contact us

Contact form

Type of fuel

Consent required

9 + 3 =

Paweł Czepiel

Export manager
Language: Russian, English
Phone. +48 85 711 94 54 ext. 17
Mobile: +48 663 45 32 22
E-mail: p.czepiel@metalfach.com.pl
Monday-Friday (from 7:00 a.m. to 3:00 p.m.)

Metal-fach Jacek Kucharewicz reserves the right to introduce changes to the technical parameters, equipment and specifications of the offered goods without prior notice. The information contained does not constitute an assurance within the meaning of Art. 4 sec. 3 and 4 of the Act of 27.07.2002. on the specific conditions of consumer sale and on the amendment to the Civil Code (hereinafter the “Act”), and do not constitute a description of the goods within the meaning of Art. 4 sec. 2 of the Act. The guide does not constitute an offer within the meaning of Art. 66 of the Civil Code.

General contact:

Opening hours:

  • Monday-Friday (7:00 a.m. – 3:00 p.m.)
  • Phone: +48 85 711 94 54 int. 17
  • E-mail: p.czepiel@metalfach.com.pl

Social Media:

Service contact:

Opening hours:

  • Monday-Friday (7:00 a.m. – 3:00 p.m.)
  • Phone: +48 85 711 94 54 int. 17
  • E-mail: p.czepiel@metalfach.com.pl

Address data:

METAL-FACH Jacek Kucharewicz

  • 16-100 Sokółka st. Sikorskiego 66
  • NIP: 545-100-10-62
  • REGON: 050073833

How to get: