BOILER
SEG EKO
General information
Technical data
Dimensions
Documentation



Fuel: Eco peas
General information
The SEG EKO boiler combines economy with convenience!
The SEG EKO boiler uses reliable and proven design solutions for many years. The components used make it an extremely effective and reliable heating device. The shape of the exchanger has been designed with high energy efficiency in mind. The boiler is equipped with a cast iron burner, which is adapted to efficient combustion of Gr II class A1 hard coal in accordance with the PN EN 303-5: 2012 standard.
Technology and security
Heat exchanger
Efficient design for quick cleaning of the exchanger from the front and from the top. The design of the boiler exchanger ensures high heat removal from the furnace.
Flue outlet
The structure of the boiler has been designed so that the outlet of the flue is at the rear. The applied design of the boiler body allows the flue to be directly led out to the chimney.
Automatic feeder
Swirlers
Limit switch
Highly efficient combustion chamber

Connectivity and functionality
Simple and intuitive boiler control
Adjust the boiler operation and room temperature to your individual needs. The PLATINUM controller is programmed in such a way as to automate all processes related to the heating of your home. The owner specifies the temperature he wants to have in the apartment, and the controller will optimize combustion in this respect. By entering the advanced settings of the driver, you can personalize each parameter. It all depends on the preferences of the user and household members!
Key Features:
Optional accessories
- Lambda probe
- ecoNET 300 internet module
- Platinum B module (buffer operation control, additional two heating circuits, 2x pump, 2x mixer, 2x thermostat)
- Platinum C module (two additional heating circuits, 2x pump, 2x mixer, 2x thermostat)
Optional accessories
- PLATINUM TOUCH room thermostat (touchscreen, wired)
- PLATINUM TOUCH x40 room thermostat (analog, wireless)
- PLATINUM TOUCH x80 room thermostat (touch, wireless)
ECOENERGIA II CAST IRON BURNER
Ekoenergia II cast iron burner – for eco-pea coal
Cast iron boiler carburizing system with manual firing up of the furnace. The eco pea burner and its components in contact with high temperature are made of cast iron. Thanks to the use of this material in the construction of the burner, these elements are more resistant to corrosion than ordinary steel, even if we use moist fuel. Cast iron elements of the burner also reduce the noise of the feeder operation. The burner and the feeding screw are made of gray ductile cast iron, resistant mainly to abrasion and high temperature. A burner constructed in this way will work reliably for many years.
Fuel: Eco peas
Screw feeder
The pin of the gear motor
Technical data of the boiler
- SEG EKO 12
- SEG EKO 15
- SEG EKO 20
- SEG EKO 26
- SEG EKO 34
- SEG EKO 50
- SEG EKO 75
- SEG EKO 100
- SEG EKO 150
- SEG EKO 200
- SEG EKO 300
PARAMETERS | UNIT S.I. | SEG EKO 12 |
Nominal thermal power | [kW] | 12 |
Boiler power range | [kW] | 3,6-12 |
The surface can be heated* | [m2] | 54-180 |
Heating area | [m2] | 2,1 |
Water capacity | [L] | 66 |
Maximum working pressure | [bar] | 3 |
Maximum working temperature | [°C] | 80 |
Test pressure | [bar] | 4,5 |
Fuel tank capacity | [L] | 190 |
Fuel tank capacity | [kg] | 139 |
Fuel | [-] | eco-pea coal Φ0-32mm |
Electrical connection | [-] | 2A; ~230V; 50Hz |
Electric power consumption | [W] | 350 |
Temperature controller setting range | [°C] | 60-80 (every 1°C) |
Chimney draft required | [Pa] | 22 |
Boiler weight | [kg] | 438 |
*A new building with very good thermal insulation was adopted for the calculations.
PARAMETERS | UNIT S.I. | SEG EKO 15 |
Nominal thermal power | [kW] | 15 |
Boiler power range | [kW] | 4,5-15 |
The surface can be heated* | [m2] | 67,5-225 |
Heating area | [m2] | 2,1 |
Water capacity | [L] | 66 |
Maximum working pressure | [bar] | 3 |
Maximum working temperature | [°C] | 80 |
Test pressure | [bar] | 4,5 |
Fuel tank capacity | [L] | 190 |
Fuel tank capacity | [kg] | 139 |
Fuel | [-] | eco-pea coal Φ0-32mm |
Electrical connection | [-] | 2A; ~230V; 50Hz |
Electric power consumption | [W] | 350 |
Temperature controller setting range | [°C] | 60-80 (every 1°C) |
Chimney draft required | [Pa] | 24 |
Boiler weight | [kg] | 448 |
*A new building with very good thermal insulation was adopted for the calculations.
PARAMETERS | UNIT S.I. | SEG EKO 20 |
Nominal thermal power | [kW] | 20 |
Boiler power range | [kW] | 6-20 |
The surface can be heated* | [m2] | 90-300 |
Heating area | [m2] | 2,54 |
Water capacity | [L] | 74 |
Maximum working pressure | [bar] | 3 |
Maximum working temperature | [°C] | 80 |
Test pressure | [bar] | 4,5 |
Fuel tank capacity | [L] | 290 |
Fuel tank capacity | [kg] | 212 |
Fuel | [-] | eco-pea coal Φ0-32mm |
Electrical connection | [-] | 2A; ~230V; 50Hz |
Electric power consumption | [W] | 350 |
Temperature controller setting range | [°C] | 60-80 (every 1°C) |
Chimney draft required | [Pa] | 26 |
Boiler weight | [kg] | 510 |
*A new building with very good thermal insulation was adopted for the calculations.
PARAMETERS | UNIT S.I. | SEG EKO 26 |
Nominal thermal power | [kW] | 26 |
Boiler power range | [kW] | 7,8-26 |
The surface can be heated* | [m2] | 117-390 |
Heating area | [m2] | 2,85 |
Water capacity | [L] | 83 |
Maximum working pressure | [bar] | 3 |
Maximum working temperature | [°C] | 80 |
Test pressure | [bar] | 4,5 |
Fuel tank capacity | [L] | 350 |
Fuel tank capacity | [kg] | 256 |
Fuel | [-] | eco-pea coal Φ0-32mm |
Electrical connection | [-] | 2A; ~230V; 50Hz |
Electric power consumption | [W] | 350 |
Temperature controller setting range | [°C] | 60-80 (every 1°C) |
Chimney draft required | [Pa] | 28 |
Boiler weight | [kg] | 539 |
*A new building with very good thermal insulation was adopted for the calculations.
PARAMETERS | UNIT S.I. | SEG EKO 34 |
Nominal thermal power | [kW] | 34 |
Boiler power range | [kW] | 10,2-34 |
The surface can be heated* | [m2] | 153-510 |
Heating area | [m2] | 3,11 |
Water capacity | [L] | 95 |
Maximum working pressure | [bar] | 3 |
Maximum working temperature | [°C] | 80 |
Test pressure | [bar] | 4,5 |
Fuel tank capacity | [L] | 350 |
Fuel tank capacity | [kg] | 256 |
Fuel | [-] | eco-pea coal Φ0-32mm |
Electrical connection | [-] | 2A; ~230V; 50Hz |
Electric power consumption | [W] | 350 |
Temperature controller setting range | [°C] | 60-80 (every 1°C) |
Chimney draft required | [Pa] | 31 |
Boiler weight | [kg] | 551 |
*A new building with very good thermal insulation was adopted for the calculations.
PARAMETERS | UNIT S.I. | SEG EKO 50 |
Nominal thermal power | [kW] | 50 |
Boiler power range | [kW] | 15-50 |
The surface can be heated* | [m2] | 225-750 |
Heating area | [m2] | – |
Water capacity | [L] | 120 |
Maximum working pressure | [bar] | 3 |
Maximum working temperature | [°C] | 80 |
Test pressure | [bar] | 4,5 |
Fuel tank capacity | [L] | 400 |
Fuel tank capacity | [kg] | 292 |
Fuel | [-] | eco-pea coal Φ0-32mm |
Electrical connection | [-] | 2A; ~230V; 50Hz |
Electric power consumption | [W] | 350 |
Temperature controller setting range | [°C] | 60-80 (every 1°C) |
Chimney draft required | [Pa] | – |
Boiler weight | [kg] | 785 |
*A new building with very good thermal insulation was adopted for the calculations.
PARAMETERS | UNIT S.I. | SEG EKO 75 |
Nominal thermal power | [kW] | 75 |
Boiler power range | [kW] | 22,5-75 |
The surface can be heated* | [m2] | 337,5-1125 |
Heating area | [m2] | – |
Water capacity | [L] | 173 |
Maximum working pressure | [bar] | 3 |
Maximum working temperature | [°C] | 80 |
Test pressure | [bar] | 4,5 |
Fuel tank capacity | [L] | 520 |
Fuel tank capacity | [kg] | 380 |
Fuel | [-] | eco-pea coal Φ0-32mm |
Electrical connection | [-] | 2A; ~230V; 50Hz |
Electric power consumption | [W] | 350 |
Temperature controller setting range | [°C] | 60-80 (every 1°C) |
Chimney draft required | [Pa] | – |
Boiler weight | [kg] | 935 |
*A new building with very good thermal insulation was adopted for the calculations.
PARAMETERS | UNIT S.I. | SEG EKO 100 |
Nominal thermal power | [kW] | 100 |
Boiler power range | [kW] | 30-100 |
The surface can be heated* | [m2] | 450-1500 |
Heating area | [m2] | – |
Water capacity | [L] | 173 |
Maximum working pressure | [bar] | 3 |
Maximum working temperature | [°C] | 80 |
Test pressure | [bar] | 4,5 |
Fuel tank capacity | [L] | 520 |
Fuel tank capacity | [kg] | 380 |
Fuel | [-] | eco-pea coal Φ0-32mm |
Electrical connection | [-] | 2A; ~230V; 50Hz |
Electric power consumption | [W] | 350 |
Temperature controller setting range | [°C] | 60-80 (every 1°C) |
Chimney draft required | [Pa] | – |
Boiler weight | [kg] | 935 |
*A new building with very good thermal insulation was adopted for the calculations.
PARAMETERS | UNIT S.I. | SEG EKO 150 |
Nominal thermal power | [kW] | 150 |
Boiler power range | [kW] | 45-150 |
The surface can be heated* | [m2] | 675-2250 |
Heating area | [m2] | – |
Water capacity | [L] | 339 |
Maximum working pressure | [bar] | 3 |
Maximum working temperature | [°C] | 80 |
Test pressure | [bar] | 4,5 |
Fuel tank capacity | [L] | 1000 |
Fuel tank capacity | [kg] | 510 |
Fuel | [-] | eco-pea coal Φ0-32mm |
Electrical connection | [-] | 2A; ~230V; 50Hz |
Electric power consumption | [W] | 350 |
Temperature controller setting range | [°C] | 60-80 (every 1°C) |
Chimney draft required | [Pa] | – |
Boiler weight | [kg] | 1350 |
*A new building with very good thermal insulation was adopted for the calculations.
PARAMETERS | UNIT S.I. | SEG EKO 200 |
Nominal thermal power | [kW] | 200 |
Boiler power range | [kW] | 60-200 |
The surface can be heated* | [m2] | 900-3000 |
Heating area | [m2] | – |
Water capacity | [L] | 760 |
Maximum working pressure | [bar] | 3 |
Maximum working temperature | [°C] | 80 |
Test pressure | [bar] | 4,5 |
Fuel tank capacity | [L] | 1500 |
Fuel tank capacity | [kg] | 1096 |
Fuel | [-] | eco-pea coal Φ0-32mm |
Electrical connection | [-] | 2A; ~230V; 50Hz |
Electric power consumption | [W] | 350 |
Temperature controller setting range | [°C] | 60-80 (every 1°C) |
Chimney draft required | [Pa] | – |
Boiler weight | [kg] | 2100 |
*A new building with very good thermal insulation was adopted for the calculations.
PARAMETERS | UNIT S.I. | SEG EKO 300 |
Nominal thermal power | [kW] | 300 |
Boiler power range | [kW] | 90-300 |
The surface can be heated* | [m2] | 1350-4500 |
Heating area | [m2] | – |
Water capacity | [L] | 1765 |
Maximum working pressure | [bar] | 3 |
Maximum working temperature | [°C] | 80 |
Test pressure | [bar] | 4,5 |
Fuel tank capacity | [L] | 1500 |
Fuel tank capacity | [kg] | 1096 |
Fuel | [-] | eco-pea coal Φ0-32mm |
Electrical connection | [-] | 2A; ~230V; 50Hz |
Electric power consumption | [W] | 350 |
Temperature controller setting range | [°C] | 60-80 (every 1°C) |
Chimney draft required | [Pa] | – |
Boiler weight | [kg] | <3000 |
*A new building with very good thermal insulation was adopted for the calculations.
CERTIFICATES, CLASS, BOILER EMISSION
- SEG EKO 12
- SEG EKO 15
- SEG EKO 20
- SEG EKO 26
- SEG EKO 34
- SEG EKO 50
- SEG EKO 75
- SEG EKO 100
- SEG EKO 150
- SEG EKO 200
- SEG EKO 300
PARAMETERS | UNIT S.I. | SEG EKO 12 |
Ecodesign | [-] | yes |
Boiler class | [-] | 5 |
Energy class | [-] | B |
Emissivity of solid particles | [mg/m3] | 16 |
PARAMETERS | UNIT S.I. | SEG EKO 15 |
Ecodesign | [-] | yes |
Boiler class | [-] | 5 |
Energy class | [-] | B |
Emissivity of solid particles | [mg/m3] | 21 |
PARAMETERS | UNIT S.I. | SEG EKO 20 |
Ecodesign | [-] | yes |
Boiler class | [-] | 5 |
Energy class | [-] | B |
Emissivity of solid particles | [mg/m3] | 19 |
PARAMETERS | UNIT S.I. | SEG EKO 26 |
Ecodesign | [-] | tak |
Boiler class | [-] | 5 |
Energy class | [-] | B |
Emissivity of solid particles | [mg/m3] | 8 |
PARAMETERS | UNIT S.I. | SEG EKO 34 |
Ecodesign | [-] | tak |
Boiler class | [-] | 5 |
Energy class | [-] | B |
Emissivity of solid particles | [mg/m3] | 8 |
PARAMETERS | UNIT S.I. | SEG EKO 50 |
Ecodesign | [-] | – |
Boiler class | [-] | – |
Energy class | [-] | B |
Emissivity of solid particles | [mg/m3] | – |
PARAMETERS | UNIT S.I. | SEG EKO 75 |
Ecodesign | [-] | – |
Boiler class | [-] | – |
Energy class | [-] | B |
Emissivity of solid particles | [mg/m3] | – |
PARAMETERS | UNIT S.I. | SEG EKO 100 |
Ecodesign | [-] | – |
Boiler class | [-] | – |
Energy class | [-] | B |
Emissivity of solid particles | [mg/m3] | – |
PARAMETERS | UNIT S.I. | SEG EKO 150 |
Ecodesign | [-] | – |
Boiler class | [-] | – |
Energy class | [-] | B |
Emissivity of solid particles | [mg/m3] | – |
PARAMETERS | UNIT S.I. | SEG EKO 200 |
Ecodesign | [-] | – |
Boiler class | [-] | – |
Energy class | [-] | B |
Emissivity of solid particles | [mg/m3] | – |
PARAMETERS | UNIT S.I. | SEG EKO 300 |
Ecodesign | [-] | – |
Boiler class | [-] | – |
Energy class | [-] | B |
Emissivity of solid particles | [mg/m3] | – |
Boiler dimensions

- SEG EKO 12
- SEG EKO 15
- SEG EKO 20
- SEG EKO 26
- SEG EKO 34
- SEG EKO 50
- SEG EKO 75
- SEG EKO 100
- SEG EKO 150
- SEG EKO 200
- SEG EKO 300
TYPE | UNIT S.I. | SEG EKO 12 |
A | [mm] | 1250 |
B1 | [mm] | 532 |
B2 | [mm] | 680 |
C1 | [mm] | 1160 |
C2 | [mm] | 1130 |
D1 | [mm] | 867 |
D2 | [mm] | 705 |
E | [mm] | 707 |
F1 | [mm] | 907 |
F2 | [mm] | 213 |
F3 | [mm] | 349 |
F4 | [mm] | 213 |
G1 | [mm] | 180 |
G2 | [cal] | 1 1/2 |
G3 | [cal] | 1 1/2 |
G4 | [cal] | 3/4 |
H | [mm] | 30 |
TYPE | UNIT S.I. | SEG EKO 15 |
A | [mm] | 1250 |
B1 | [mm] | 532 |
B2 | [mm] | 680 |
C1 | [mm] | 1160 |
C2 | [mm] | 1130 |
D1 | [mm] | 867 |
D2 | [mm] | 705 |
E | [mm] | 707 |
F1 | [mm] | 907 |
F2 | [mm] | 213 |
F3 | [mm] | 349 |
F4 | [mm] | 213 |
G1 | [mm] | 180 |
G2 | [cal] | 1 1/2 |
G3 | [cal] | 1 1/2 |
G4 | [cal] | 3/4 |
H | [mm] | 30 |
TYPE | UNIT S.I. | SEG EKO 20 |
A | [mm] | 1250 |
B1 | [mm] | 532 |
B2 | [mm] | 680 |
C1 | [mm] | 1356 |
C2 | [mm] | 1326 |
D1 | [mm] | 905 |
D2 | [mm] | 745 |
E | [mm] | 720 |
F1 | [mm] | 1104 |
F2 | [mm] | 247 |
F3 | [mm] | 359 |
F4 | [mm] | 207 |
G1 | [mm] | 180 |
G2 | [cal] | 1 1/2 |
G3 | [cal] | 1 1/2 |
G4 | [cal] | 3/4 |
H | [mm] | 30 |
TYPE | UNIT S.I. | SEG EKO 26 |
A | [mm] | 1250 |
B1 | [mm] | 532 |
B2 | [mm] | 680 |
C1 | [mm] | 1413 |
C2 | [mm] | 1383 |
D1 | [mm] | 955 |
D2 | [mm] | 796 |
E | [mm] | 776 |
F1 | [mm] | 1160 |
F2 | [mm] | 245 |
F3 | [mm] | 409 |
F4 | [mm] | 205 |
G1 | [mm] | 180 |
G2 | [cal] | 1 1/2 |
G3 | [cal] | 1 1/2 |
G4 | [cal] | 3/4 |
H | [mm] | 30 |
TYPE | UNIT S.I. | SEG EKO 34 |
A | [mm] | 1300 |
B1 | [mm] | 582 |
B2 | [mm] | 680 |
C1 | [mm] | 1413 |
C2 | [mm] | 1383 |
D1 | [mm] | 955 |
D2 | [mm] | 796 |
E | [mm] | 776 |
F1 | [mm] | 1160 |
F2 | [mm] | 245 |
F3 | [mm] | 409 |
F4 | [mm] | 205 |
G1 | [mm] | 180 |
G2 | [cal] | 1 1/2 |
G3 | [cal] | 1 1/2 |
G4 | [cal] | 3/4 |
H | [mm] | 30 |
TYPE | UNIT S.I. | SEG EKO 50 |
A | [mm] | 1443 |
B1 | [mm] | 681 |
B2 | [mm] | 680 |
C1 | [mm] | 1490 |
C2 | [mm] | 1460 |
D1 | [mm] | 1218 |
D2 | [mm] | 1060 |
E | [mm] | 850 |
F1 | [mm] | 1110 |
F2 | [mm] | 337 |
F3 | [mm] | 536 |
F4 | [mm] | 190 |
G1 | [mm] | 220 |
G2 | [cal] | 1 1/2 |
G3 | [cal] | 1 1/2 |
G4 | [cal] | 3/4 |
H | [mm] | 30 |
TYPE | UNIT S.I. | SEG EKO 75 |
A | [mm] | 1505 |
B1 | [mm] | 793 |
B2 | [mm] | 680 |
C1 | [mm] | 1440 |
C2 | [mm] | 1410 |
D1 | [mm] | 1413 |
D2 | [mm] | 1175 |
E | [mm] | 850 |
F1 | [mm] | 1115 |
F2 | [mm] | 350 |
F3 | [mm] | 545 |
F4 | [mm] | 175 |
G1 | [mm] | 220 |
G2 | [cal] | 1 1/2 |
G3 | [cal] | 1 1/2 |
G4 | [cal] | 3/4 |
H | [mm] | 30 |
TYPE | UNIT S.I. | SEG EKO 100 |
A | [mm] | 1505 |
B1 | [mm] | 795 |
B2 | [mm] | 700 |
C1 | [mm] | 1620 |
C2 | [mm] | 1590 |
D1 | [mm] | 1570 |
D2 | [mm] | 1325 |
E | [mm] | 1075 |
F1 | [mm] | 1215 |
F2 | [mm] | 300 |
F3 | [mm] | 695 |
F4 | [mm] | 175 |
G1 | [mm] | 220 |
G2 | [cal] | 1 1/2 |
G3 | [cal] | 1 1/2 |
G4 | [cal] | 3/4 |
H | [mm] | 30 |
TYPE | UNIT S.I. | SEG EKO 150 |
A | [mm] | 1965 |
B1 | [mm] | 955 |
B2 | [mm] | 1015 |
C1 | [mm] | 2200 |
C2 | [mm] | 2170 |
D1 | [mm] | 1560 |
D2 | [mm] | 1260 |
E | [mm] | 1105 |
F1 | [mm] | 2005 |
F2 | [mm] | 165 |
F3 | [mm] | 515 |
F4 | [mm] | 143 |
G1 | [mm] | 250 |
G2 | [cal] | 1 1/2 |
G3 | [cal] | 1 1/2 |
G4 | [cal] | 3/4 |
H | [mm] | 30 |
TYPE | UNIT S.I. | SEG EKO 200 |
A | [mm] | 2500 |
B1 | [mm] | 1240 |
B2 | [mm] | 1200 |
C1 | [mm] | 2230 |
C2 | [mm] | 2200 |
D1 | [mm] | 2240 |
D2 | [mm] | 1690 |
E | [mm] | 1190 |
F1 | [mm] | 1720 |
F2 | [mm] | 375 |
F3 | [mm] | 890 |
F4 | [mm] | 330 |
G1 | [mm] | 350 |
G2 | [mm] | 101,6 |
G3 | [mm] | 101,6 |
G4 | [cal] | 1 1/4 |
H | [mm] | 30 |
TYPE | UNIT S.I. | SEG EKO 300 |
A | [mm] | 3140 |
B1 | [mm] | 1820 |
B2 | [mm] | 1200 |
C1 | [mm] | 2220 |
C2 | [mm] | 2190 |
D1 | [mm] | – |
D2 | [mm] | 2545 |
E | [mm] | 1190 |
F1 | [mm] | 1722 |
F2 | [mm] | 320 |
F3 | [mm] | 1774 |
F4 | [mm] | – |
G1 | [mm] | – |
G2 | [mm] | 101,6 |
G3 | [mm] | 101,6 |
G4 | [cal] | 1 1/4 |
H | [mm] | 30 |
Boiler documentation
DTR statement
Technical and operational documentation for the SEG EKO boiler
Driver manual
PLATINUM driver manual
Energy label
B energy class
Product sheet
According to EU Regulation 2015/1187 supplementing Directive 2009/125 / EC of the European Parliament and of the Council
EcoDesign certificate
The boiler complies with the requirements of the EcoDesign standard
Class 5 Certificate
The boiler complies with the requirements of PN-EN 303-5: 2012
Contact us
Contact form
Paweł Czepiel
Export manager
Language: Russian, English
Phone. +48 85 711 94 54 ext. 17
Mobile: +48 663 45 32 22
E-mail: p.czepiel@metalfach.com.pl
Monday-Friday (from 7:00 a.m. to 3:00 p.m.)
General contact:
- Mon.-Fri. 7:00a.m.-3:00p.m.
- Phone: +48 85 711 94 54 int. 17
- E-mail: p.czepiel@metalfach.com.pl
General contact:
Service contact:
- Mon.-Fri. 7:00a.m.–3:00 p.m.
- Phone: +48 85 711 94 54 int. 17
- E-mail: p.czepiel@metalfach.com.pl
Address data:
- st. Sikorskiego 66, 16-100 Sokółka, Poland
- NIP: 545-100-10-62
- REGON: 050073833