fbpx

BOILER

SEG EKO

General information

Technical data

Dimensions

Documentation

Z
Available powers: 12kW | 15kW | 20kW | 26kW | 34kW | 50kW | 75kW | 100kW | 150kW | 200kW | 300kW
Z

Fuel: Eco peas

Z
Certificates: EcoDesign | 5th class
Z
Energy class: B

General information

The SEG EKO boiler combines economy with convenience!

The SEG EKO boiler uses reliable and proven design solutions for many years. The components used make it an extremely effective and reliable heating device. The shape of the exchanger has been designed with high energy efficiency in mind. The boiler is equipped with a cast iron burner, which is adapted to efficient combustion of Gr II class A1 hard coal in accordance with the PN EN 303-5: 2012 standard.

Technology and security

Z

Heat exchanger

Horizontal and vertical convection channels | regimental
Efficient design for quick cleaning of the exchanger from the front and from the top. The design of the boiler exchanger ensures high heat removal from the furnace.
Z

Flue outlet

At the back of the boiler
The structure of the boiler has been designed so that the outlet of the flue is at the rear. The applied design of the boiler body allows the flue to be directly led out to the chimney.
Z

Automatic feeder

The PLATINUM controller, on the basis of information received from sensors, determines the demand for fuel and doses it the right amount. The process of fuel combustion itself is therefore very economical, ecological and does not require additional service on the part of the user.
Z

Swirlers

The swirlers installed in the convection channels effectively reduce the speed of the exhaust gas outlet, maintaining high heat reception by the water cry.
Z

Limit switch

For your safety, the boiler is equipped with a limit switch. The end protection system is placed in the boiler door and in the hopper flap. Each opening causes the burner and other elements of the boiler to stop working automatically until they are closed again.
Z

Highly efficient combustion chamber

Thanks to the use of ceramic fittings with the burner, the boiler achieves high efficiency. This technological solution increases the temperature in the combustion chamber and stops the particles floating above the furnace, burning them up. As a result of this process, the thermal efficiency of the furnace increases, and the flue gas has a reduced amount of substances harmful to the environment to a minimum.

Connectivity and functionality

Simple and intuitive boiler control

Adjust the boiler operation and room temperature to your individual needs. The PLATINUM controller is programmed in such a way as to automate all processes related to the heating of your home. The owner specifies the temperature he wants to have in the apartment, and the controller will optimize combustion in this respect. By entering the advanced settings of the driver, you can personalize each parameter. It all depends on the preferences of the user and household members!

Key Features:

E
Pump (DHW, C.H.1, C.O.2, circulation, additional)
E
Two CH.1 and CH.2 mixing circuits with a room thermostat
E
RTC clock with weekly timer
E
Weather control
E
Winter / summer operation mode
E
FuzzyLogic & PID
Z

Optional accessories

  • Lambda probe
  • ecoNET 300 internet module
  • Platinum B module (buffer operation control, additional two heating circuits, 2x pump, 2x mixer, 2x thermostat)
  • Platinum C module (two additional heating circuits, 2x pump, 2x mixer, 2x thermostat)
Z

Optional accessories

  • PLATINUM TOUCH room thermostat (touchscreen, wired)
  • PLATINUM TOUCH x40 room thermostat (analog, wireless)
  • PLATINUM TOUCH x80 room thermostat (touch, wireless)

ECOENERGIA II CAST IRON BURNER

Ekoenergia II cast iron burner – for eco-pea coal

Cast iron boiler carburizing system with manual firing up of the furnace. The eco pea burner and its components in contact with high temperature are made of cast iron. Thanks to the use of this material in the construction of the burner, these elements are more resistant to corrosion than ordinary steel, even if we use moist fuel. Cast iron elements of the burner also reduce the noise of the feeder operation. The burner and the feeding screw are made of gray ductile cast iron, resistant mainly to abrasion and high temperature. A burner constructed in this way will work reliably for many years.

Z

Fuel: Eco peas

Ecological fuel from the depths of the earth. Eco pea fuel is produced on the basis of hard coal. The prefix “eco” means that it meets the stricter gas emission standards. Eco-pea fuel has a low sulfur content, a small amount of ash and low humidity. While burning, it produces much less harmful compounds than ordinary coal.
Z

Screw feeder

The screw feeder doses fuel precisely, is resistant to abrasion, corrosion and high temperature.
Z

The pin of the gear motor

Prevents damage to the gearmotor. When there is an element in the feeder that the screw will not be able to push out, the pin will break, which will protect the boiler against serious damage to the feeding system.

Technical data of the boiler

PARAMETERSUNIT S.I.SEG EKO 12
Nominal thermal power[kW]12
Boiler power range[kW]3,6-12
The surface can be heated*[m2]54-180
Heating area[m2]2,1
Water capacity[L]66
Maximum working pressure[bar]3
Maximum working temperature[°C]80
Test pressure[bar]4,5
Fuel tank capacity[L]190
Fuel tank capacity[kg]139
Fuel[-]eco-pea coal Φ0-32mm
Electrical connection[-]2A; ~230V; 50Hz
Electric power consumption[W]350
Temperature controller setting range[°C]60-80 (every 1°C)
Chimney draft required[Pa]22
Boiler weight[kg]438

*A new building with very good thermal insulation was adopted for the calculations.

PARAMETERSUNIT S.I.SEG EKO 15
Nominal thermal power[kW]15
Boiler power range[kW]4,5-15
The surface can be heated*[m2]67,5-225
Heating area[m2]2,1
Water capacity[L]66
Maximum working pressure[bar]3
Maximum working temperature[°C]80
Test pressure[bar]4,5
Fuel tank capacity[L]190
Fuel tank capacity[kg]139
Fuel[-]eco-pea coal Φ0-32mm
Electrical connection[-]2A; ~230V; 50Hz
Electric power consumption[W]350
Temperature controller setting range[°C]60-80 (every 1°C)
Chimney draft required[Pa]24
Boiler weight[kg]448

*A new building with very good thermal insulation was adopted for the calculations.

PARAMETERSUNIT S.I.SEG EKO 20
Nominal thermal power[kW]20
Boiler power range[kW]6-20
The surface can be heated*[m2]90-300
Heating area[m2]2,54
Water capacity[L]74
Maximum working pressure[bar]3
Maximum working temperature[°C]80
Test pressure[bar]4,5
Fuel tank capacity[L]290
Fuel tank capacity[kg]212
Fuel[-]eco-pea coal Φ0-32mm
Electrical connection[-]2A; ~230V; 50Hz
Electric power consumption[W]350
Temperature controller setting range[°C]60-80 (every 1°C)
Chimney draft required[Pa]26
Boiler weight[kg]510

*A new building with very good thermal insulation was adopted for the calculations.

PARAMETERSUNIT S.I.SEG EKO 26
Nominal thermal power[kW]26
Boiler power range[kW]7,8-26
The surface can be heated*[m2]117-390
Heating area[m2]2,85
Water capacity[L]83
Maximum working pressure[bar]3
Maximum working temperature[°C]80
Test pressure[bar]4,5
Fuel tank capacity[L]350
Fuel tank capacity[kg]256
Fuel[-]eco-pea coal Φ0-32mm
Electrical connection[-]2A; ~230V; 50Hz
Electric power consumption[W]350
Temperature controller setting range[°C]60-80 (every 1°C)
Chimney draft required[Pa]28
Boiler weight[kg]539

*A new building with very good thermal insulation was adopted for the calculations.

PARAMETERSUNIT S.I.SEG EKO 34
Nominal thermal power[kW]34
Boiler power range[kW]10,2-34
The surface can be heated*[m2]153-510
Heating area[m2]3,11
Water capacity[L]95
Maximum working pressure[bar]3
Maximum working temperature[°C]80
Test pressure[bar]4,5
Fuel tank capacity[L]350
Fuel tank capacity[kg]256
Fuel[-]eco-pea coal Φ0-32mm
Electrical connection[-]2A; ~230V; 50Hz
Electric power consumption[W]350
Temperature controller setting range[°C]60-80 (every 1°C)
Chimney draft required[Pa]31
Boiler weight[kg]551

*A new building with very good thermal insulation was adopted for the calculations.

PARAMETERSUNIT S.I.SEG EKO 50
Nominal thermal power[kW]50
Boiler power range[kW]15-50
The surface can be heated*[m2]225-750
Heating area[m2]
Water capacity[L]120
Maximum working pressure[bar]3
Maximum working temperature[°C]80
Test pressure[bar]4,5
Fuel tank capacity[L]400
Fuel tank capacity[kg]292
Fuel[-]eco-pea coal Φ0-32mm
Electrical connection[-]2A; ~230V; 50Hz
Electric power consumption[W]350
Temperature controller setting range[°C]60-80 (every 1°C)
Chimney draft required[Pa]
Boiler weight[kg]785

*A new building with very good thermal insulation was adopted for the calculations.

PARAMETERSUNIT S.I.SEG EKO 75
Nominal thermal power[kW]75
Boiler power range[kW]22,5-75
The surface can be heated*[m2]337,5-1125
Heating area[m2]
Water capacity[L]173
Maximum working pressure[bar]3
Maximum working temperature[°C]80
Test pressure[bar]4,5
Fuel tank capacity[L]520
Fuel tank capacity[kg]380
Fuel[-]eco-pea coal Φ0-32mm
Electrical connection[-]2A; ~230V; 50Hz
Electric power consumption[W]350
Temperature controller setting range[°C]60-80 (every 1°C)
Chimney draft required[Pa]
Boiler weight[kg]935

*A new building with very good thermal insulation was adopted for the calculations.

PARAMETERSUNIT S.I.SEG EKO 100
Nominal thermal power[kW]100
Boiler power range[kW]30-100
The surface can be heated*[m2]450-1500
Heating area[m2]
Water capacity[L]173
Maximum working pressure[bar]3
Maximum working temperature[°C]80
Test pressure[bar]4,5
Fuel tank capacity[L]520
Fuel tank capacity[kg]380
Fuel[-]eco-pea coal Φ0-32mm
Electrical connection[-]2A; ~230V; 50Hz
Electric power consumption[W]350
Temperature controller setting range[°C]60-80 (every 1°C)
Chimney draft required[Pa]
Boiler weight[kg]935

*A new building with very good thermal insulation was adopted for the calculations.

PARAMETERSUNIT S.I.SEG EKO 150
Nominal thermal power[kW]150
Boiler power range[kW]45-150
The surface can be heated*[m2]675-2250
Heating area[m2]
Water capacity[L]339
Maximum working pressure[bar]3
Maximum working temperature[°C]80
Test pressure[bar]4,5
Fuel tank capacity[L]1000
Fuel tank capacity[kg]510
Fuel[-]eco-pea coal Φ0-32mm
Electrical connection[-]2A; ~230V; 50Hz
Electric power consumption[W]350
Temperature controller setting range[°C]60-80 (every 1°C)
Chimney draft required[Pa]
Boiler weight[kg]1350

*A new building with very good thermal insulation was adopted for the calculations.

PARAMETERSUNIT S.I.SEG EKO 200
Nominal thermal power[kW]200
Boiler power range[kW]60-200
The surface can be heated*[m2]900-3000
Heating area[m2]
Water capacity[L]760
Maximum working pressure[bar]3
Maximum working temperature[°C]80
Test pressure[bar]4,5
Fuel tank capacity[L]1500
Fuel tank capacity[kg]1096
Fuel[-]eco-pea coal Φ0-32mm
Electrical connection[-]2A; ~230V; 50Hz
Electric power consumption[W]350
Temperature controller setting range[°C]60-80 (every 1°C)
Chimney draft required[Pa]
Boiler weight[kg]2100

*A new building with very good thermal insulation was adopted for the calculations.

PARAMETERSUNIT S.I.SEG EKO 300
Nominal thermal power[kW]300
Boiler power range[kW]90-300
The surface can be heated*[m2]1350-4500
Heating area[m2]
Water capacity[L]1765
Maximum working pressure[bar]3
Maximum working temperature[°C]80
Test pressure[bar]4,5
Fuel tank capacity[L]1500
Fuel tank capacity[kg]1096
Fuel[-]eco-pea coal Φ0-32mm
Electrical connection[-]2A; ~230V; 50Hz
Electric power consumption[W]350
Temperature controller setting range[°C]60-80 (every 1°C)
Chimney draft required[Pa]
Boiler weight[kg]<3000

*A new building with very good thermal insulation was adopted for the calculations.

CERTIFICATES, CLASS, BOILER EMISSION

PARAMETERSUNIT S.I.SEG EKO 12
Ecodesign[-]yes
Boiler class[-]5
Energy class[-]B
Emissivity of solid particles[mg/m3]16
PARAMETERSUNIT S.I.SEG EKO 15
Ecodesign[-]yes
Boiler class[-]5
Energy class[-]B
Emissivity of solid particles[mg/m3]21
PARAMETERSUNIT S.I.SEG EKO 20
Ecodesign[-]yes
Boiler class[-]5
Energy class[-]B
Emissivity of solid particles[mg/m3]19
PARAMETERSUNIT S.I.SEG EKO 26
Ecodesign[-]tak
Boiler class[-]5
Energy class[-]B
Emissivity of solid particles[mg/m3]8
PARAMETERSUNIT S.I.SEG EKO 34
Ecodesign[-]tak
Boiler class[-]5
Energy class[-]B
Emissivity of solid particles[mg/m3]8
PARAMETERSUNIT S.I.SEG EKO 50
Ecodesign[-]
Boiler class[-]
Energy class[-]B
Emissivity of solid particles[mg/m3]
PARAMETERSUNIT S.I.SEG EKO 75
Ecodesign[-]
Boiler class[-]
Energy class[-]B
Emissivity of solid particles[mg/m3]
PARAMETERSUNIT S.I.SEG EKO 100
Ecodesign[-]
Boiler class[-]
Energy class[-]B
Emissivity of solid particles[mg/m3]
PARAMETERSUNIT S.I.SEG EKO 150
Ecodesign[-]
Boiler class[-]
Energy class[-]B
Emissivity of solid particles[mg/m3]
PARAMETERSUNIT S.I.SEG EKO 200
Ecodesign[-]
Boiler class[-]
Energy class[-]B
Emissivity of solid particles[mg/m3]
PARAMETERSUNIT S.I.SEG EKO 300
Ecodesign[-]
Boiler class[-]
Energy class[-]B
Emissivity of solid particles[mg/m3]

Boiler dimensions

TYPEUNIT S.I.SEG EKO 12
A[mm]1250
B1[mm]532
B2[mm]680
C1[mm]1160
C2[mm]1130
D1[mm]867
D2[mm]705
E[mm]707
F1[mm]907
F2[mm]213
F3[mm]349
F4[mm]213
G1[mm]180
G2[cal]1 1/2
G3[cal]1 1/2
G4[cal]3/4
H[mm]30
TYPEUNIT S.I.SEG EKO 15
A[mm]1250
B1[mm]532
B2[mm]680
C1[mm]1160
C2[mm]1130
D1[mm]867
D2[mm]705
E[mm]707
F1[mm]907
F2[mm]213
F3[mm]349
F4[mm]213
G1[mm]180
G2[cal]1 1/2
G3[cal]1 1/2
G4[cal]3/4
H[mm]30
TYPEUNIT S.I.SEG EKO 20
A[mm]1250
B1[mm]532
B2[mm]680
C1[mm]1356
C2[mm]1326
D1[mm]905
D2[mm]745
E[mm]720
F1[mm]1104
F2[mm]247
F3[mm]359
F4[mm]207
G1[mm]180
G2[cal]1 1/2
G3[cal]1 1/2
G4[cal]3/4
H[mm]30
TYPEUNIT S.I.SEG EKO 26
A[mm]1250
B1[mm]532
B2[mm]680
C1[mm]1413
C2[mm]1383
D1[mm]955
D2[mm]796
E[mm]776
F1[mm]1160
F2[mm]245
F3[mm]409
F4[mm]205
G1[mm]180
G2[cal]1 1/2
G3[cal]1 1/2
G4[cal]3/4
H[mm]30
TYPEUNIT S.I.SEG EKO 34
A[mm]1300
B1[mm]582
B2[mm]680
C1[mm]1413
C2[mm]1383
D1[mm]955
D2[mm]796
E[mm]776
F1[mm]1160
F2[mm]245
F3[mm]409
F4[mm]205
G1[mm]180
G2[cal]1 1/2
G3[cal]1 1/2
G4[cal]3/4
H[mm]30
TYPEUNIT S.I.SEG EKO 50
A[mm]1443
B1[mm]681
B2[mm]680
C1[mm]1490
C2[mm]1460
D1[mm]1218
D2[mm]1060
E[mm]850
F1[mm]1110
F2[mm]337
F3[mm]536
F4[mm]190
G1[mm]220
G2[cal]1 1/2
G3[cal]1 1/2
G4[cal]3/4
H[mm]30
TYPEUNIT S.I.SEG EKO 75
A[mm]1505
B1[mm]793
B2[mm]680
C1[mm]1440
C2[mm]1410
D1[mm]1413
D2[mm]1175
E[mm]850
F1[mm]1115
F2[mm]350
F3[mm]545
F4[mm]175
G1[mm]220
G2[cal]1 1/2
G3[cal]1 1/2
G4[cal]3/4
H[mm]30
TYPEUNIT S.I.SEG EKO 100
A[mm]1505
B1[mm]795
B2[mm]700
C1[mm]1620
C2[mm]1590
D1[mm]1570
D2[mm]1325
E[mm]1075
F1[mm]1215
F2[mm]300
F3[mm]695
F4[mm]175
G1[mm]220
G2[cal]1 1/2
G3[cal]1 1/2
G4[cal]3/4
H[mm]30
TYPEUNIT S.I.SEG EKO 150
A[mm]1965
B1[mm]955
B2[mm]1015
C1[mm]2200
C2[mm]2170
D1[mm]1560
D2[mm]1260
E[mm]1105
F1[mm]2005
F2[mm]165
F3[mm]515
F4[mm]143
G1[mm]250
G2[cal]1 1/2
G3[cal]1 1/2
G4[cal]3/4
H[mm]30
TYPEUNIT S.I.SEG EKO 200
A[mm]2500
B1[mm]1240
B2[mm]1200
C1[mm]2230
C2[mm]2200
D1[mm]2240
D2[mm]1690
E[mm]1190
F1[mm]1720
F2[mm]375
F3[mm]890
F4[mm]330
G1[mm]350
G2[mm]101,6
G3[mm]101,6
G4[cal]1 1/4
H[mm]30
TYPEUNIT S.I.SEG EKO 300
A[mm]3140
B1[mm]1820
B2[mm]1200
C1[mm]2220
C2[mm]2190
D1[mm]
D2[mm]2545
E[mm]1190
F1[mm]1722
F2[mm]320
F3[mm]1774
F4[mm]
G1[mm]
G2[mm]101,6
G3[mm]101,6
G4[cal]1 1/4
H[mm]30

Boiler documentation

Z

DTR statement

Technical and operational documentation for the SEG EKO PLUS boiler

Z

Driver manual

PLATINUM driver manual

Z

Energy label

B energy class

Z

Product sheet

According to EU Regulation 2015/1187 supplementing Directive 2009/125 / EC of the European Parliament and of the Council

Z

EcoDesign certificate

The boiler complies with the requirements of the EcoDesign standard

Z

Class 5 Certificate

The boiler complies with the requirements of PN-EN 303-5: 2012

Contact us

Contact form

Type of fuel

Consent required

15 + 8 =

Paweł Czepiel

Export manager
Language: Russian, English
Phone. +48 85 711 94 54 ext. 17
Mobile: +48 663 45 32 22
E-mail: p.czepiel@metalfach.com.pl
Monday-Friday (from 7:00 a.m. to 3:00 p.m.)

Metal-fach Jacek Kucharewicz reserves the right to introduce changes to the technical parameters, equipment and specifications of the offered goods without prior notice. The information contained does not constitute an assurance within the meaning of Art. 4 sec. 3 and 4 of the Act of 27.07.2002. on the specific conditions of consumer sale and on the amendment to the Civil Code (hereinafter the “Act”), and do not constitute a description of the goods within the meaning of Art. 4 sec. 2 of the Act. The guide does not constitute an offer within the meaning of Art. 66 of the Civil Code.

General contact:

Opening hours:

  • Monday-Friday (7:00 a.m. – 3:00 p.m.)
  • Phone: +48 85 711 94 54 int. 17
  • E-mail: p.czepiel@metalfach.com.pl

Social Media:

Service contact:

Opening hours:

  • Monday-Friday (7:00 a.m. – 3:00 p.m.)
  • Phone: +48 85 711 94 54 int. 17
  • E-mail: p.czepiel@metalfach.com.pl

Address data:

METAL-FACH Jacek Kucharewicz

  • 16-100 Sokółka st. Sikorskiego 66
  • NIP: 545-100-10-62
  • REGON: 050073833

How to get: