fbpx

SEG EKO boiler available in the power of 12,15,20,26,34 kW

SEG EKO

The boiler has EcoDesign and Class 5 certification.

Boiler specifications and dimensions

Check the parameters of the SEG EKO boiler and its dimensions.

Information on the boiler

Learn more about the design and functions of the SEG EKO boiler.

Documentation for the boiler

All necessary documents for SEG EKO boiler to download.

SEG EKO

Boiler construction

Combining economy with efficiency!

The SEG EKO boiler uses reliable and proven design solutions. The components used make it an extremely efficient and reliable heating device. The shape of the exchanger was designed for high energy efficiency. It is equipped with a cast-iron burner, which is adapted to efficient burning of hard coal of the Gr II class a1 sort according to the PN EN 303-5:2012 standard. After installing the ecoNET internet module, the boiler functions can be managed from a telephone or computer. The boiler is an ideal solution for those who appreciate economy and reliability.

Horizontal and vertical convection channels

Efficient construction adapted to quick cleaning of the exchanger from the front and from above. The design of the boiler exchanger ensures a high heat reception from the furnace. The boiler is equipped with ceramic fittings which increase its efficiency.

Outlet of the flue pipe at the back of the boiler

The construction of the boiler is designed so that the flue outlet is at the back. The applied constructional solution of the boiler body allows for direct outlet of the flue pipe to the chimney.

Automatic feeder

The controller, on the basis of measurements from combustion sensors, calculates the demand for fuel and doses the appropriate amount of it. Thanks to this, the combustion process is economical, ecological and does not require any additional user service. The whole system is secured by a pin of the geared motor, preventing its damage.

Valve-spinners

The swirls installed in the convection ducts effectively reduce the speed of the flue gas outlet from inside the boiler. This results in an increase in the heat output from the flue gases, and savings resulting from lower fuel demand.

Limit switch

In the interests of your safety, the boiler is equipped with a limit switch. The end protection system is located in the boiler door and tank flap. Each opening of the door or tank flap in the furnace automatically stops the burner operation until it is closed again. You care about the environment, we care about your safety.

Highly efficient combustion chamber

Thanks to the use of ceramic fittings together with the burner, the boiler achieves high efficiency. This technological solution raises the temperature in the combustion chamber and stops the particles floating above the hearth, burning them. As a result of this process, the thermal efficiency of the furnace increases and the exhaust gases are reduced to a minimum amount of compounds harmful to the environment.

SEG EKO 

PLATINUM controller

Simple and intuitive boiler control

Adjust boiler operation and room temperature to your own individual needs. The controller is programmed to automate all processes related to heating your home. The owner specifies the temperature he wants to have in his flat and the controller will optimise combustion in this respect. By entering the advanced settings of the controller you have the possibility to personalise each parameter. It all depends on your and your household’s preferences!

Sterownik kotła c.o. PLATINUM.

Key functions

– Pump (DHW, C.H.1, C.O.2, circulation, additional);

– Two CH.1 and CH.2 mixing circuits with a room thermostat;

– RTC clock with weekly programmer;

– Weather control;

– Winter / summer operation mode;

– FuzzyLogic & PID.

EcoNET internet module

Additional equipment

Mobile temperature setting via smartphone: control, monitor, compare statistics. The Internet module is not only about remote control of the boiler operation, it is also a record and register of the heating process in your home. Thanks to the ecoNET internet module (wired, wi-fi) you can gain control over your expenses and nothing will surprise you anymore!

Room thermostat

Additional equipment

Comfortable control of the boiler and its parameters without looking into the boiler room. The panel displays all the information provided by the boiler controller and enables the introduction of changes in boiler operation. The controller supports dedicated analogue and touch, wired and wireless thermostats.

Additional equipment

Lambda sensor

ecoNET Internet module (wired, wi-fi)

– Room thermostat PLATINUM TOUCH (tactile, wired)

– Room thermostat PLATINUM TOUCH x40 (analogue, wireless)

– Room thermostat PLATINUM TOUCH x80 (tactile, wireless)

Platinum B module

Platinum C module

SEG EKO

EKOENERGIA II cast iron burner

EKOENERGIA II cast iron burner

Cast iron boiler carburizing system with manual furnace firing. The eco pea burner and its components in contact with high temperature are made of cast iron. Thanks to the use of this material in the construction of the burner, these elements are more resistant to corrosion than ordinary steel, even if we use moist fuel. Cast iron elements of the burner also reduce the noise of the feeder. The burner and the feeding screw are made of gray ductile cast iron, resistant mainly to abrasion and high temperature. A burner constructed in such a way will work reliably for many years.

Sterownik z 5 calowmy wyświetlaczem do pieca centralnego ogrzewania.

Fuel: Eco peas

Green fuel straight from the ground. The eco-fuel is produced on the basis of hard coal. The prefix “eco” means that it meets the stricter gas emission standards. Eco-pea fuel has a negligible sulphur content, low ash content and low humidity. By burning, it produces far less harmful compounds than ordinary coal.

Auger feeder

It doses fuel precisely, is resistant to abrasion and high temperature.

O

The pin of the gear motor

Prevents damage to the geared motor. When there is an element in the feeder that the auger will not be able to push out, the pin will break, which will protect the boiler against serious damage to the feeding system.

SEG EKO

Boiler specifications

PARAMETERSUNIT S.I.SEG EKO 12
Nominal thermal power[kW]12
Boiler power range[kW]3,6-12
The surface can be heated*[m2]54-180
Heating area[m2]2,1
Water capacity[L]60
Maximum working pressure[bar]3
Maximum working temperature[°C]85
Test pressure[bar]4,5
Fuel tank capacity[L]190
Fuel tank capacity[kg]139
Fuel[-]eco-pea coal Φ0-32mm
Electrical connection[-]~230V; 50Hz
Electric power consumption[W]350
Temperature controller setting range[°C]60-85 (every 1°C)
Chimney draft required[Pa]22
Boiler weight[kg]438

*A new building with very good thermal insulation was adopted for the calculations.

PARAMETERSUNIT S.I.SEG EKO 15
Nominal thermal power[kW]15
Boiler power range[kW]4,5-15
The surface can be heated*[m2]67,5-225
Heating area[m2]2,1
Water capacity[L]60
Maximum working pressure[bar]3
Maximum working temperature[°C]85
Test pressure[bar]4,5
Fuel tank capacity[L]190
Fuel tank capacity[kg]139
Fuel[-]eco-pea coal Φ0-32mm
Electrical connection[-]~230V; 50Hz
Electric power consumption[W]350
Temperature controller setting range[°C]60-85 (every 1°C)
Chimney draft required[Pa]24
Boiler weight[kg]448

*A new building with very good thermal insulation was adopted for the calculations.

PARAMETERSUNIT S.I.SEG EKO 20
Nominal thermal power[kW]20
Boiler power range[kW]6-20
The surface can be heated*[m2]90-300
Heating area[m2]2,54
Water capacity[L]68
Maximum working pressure[bar]3
Maximum working temperature[°C]85
Test pressure[bar]4,5
Fuel tank capacity[L]290
Fuel tank capacity[kg]212
Fuel[-]eco-pea coal Φ0-32mm
Electrical connection[-]~230V; 50Hz
Electric power consumption[W]350
Temperature controller setting range[°C]60-85 (every 1°C)
Chimney draft required[Pa]26
Boiler weight[kg]510

*A new building with very good thermal insulation was adopted for the calculations.

PARAMETERSUNIT S.I.SEG EKO 26
Nominal thermal power[kW]26
Boiler power range[kW]7,8-26
The surface can be heated*[m2]117-390
Heating area[m2]2,85
Water capacity[L]73
Maximum working pressure[bar]3
Maximum working temperature[°C]85
Test pressure[bar]4,5
Fuel tank capacity[L]350
Fuel tank capacity[kg]256
Fuel[-]eco-pea coal Φ0-32mm
Electrical connection[-]~230V; 50Hz
Electric power consumption[W]350
Temperature controller setting range[°C]60-85 (every 1°C)
Chimney draft required[Pa]28
Boiler weight[kg]535

*A new building with very good thermal insulation was adopted for the calculations.

PARAMETERSUNIT S.I.SEG EKO 34
Nominal thermal power[kW]34
Boiler power range[kW]10,2-34
The surface can be heated*[m2]153-510
Heating area[m2]3,11
Water capacity[L]95
Maximum working pressure[bar]3
Maximum working temperature[°C]85
Test pressure[bar]4,5
Fuel tank capacity[L]350
Fuel tank capacity[kg]256
Fuel[-]eco-pea coal Φ0-32mm
Electrical connection[-]~230V; 50Hz
Electric power consumption[W]350
Temperature controller setting range[°C]60-85 (every 1°C)
Chimney draft required[Pa]31
Boiler weight[kg]551

*A new building with very good thermal insulation was adopted for the calculations.

PARAMETERSUNIT S.I.SEG EKO 12
Ecodesign[-]yes
Boiler class[-]5
Energy class[-]B
PARAMETERSUNIT S.I.SEG EKO 15
Ecodesign[-]yes
Boiler class[-]5
Energy class[-]B
PARAMETERSUNIT S.I.SEG EKO 20
Ecodesign[-]yes
Boiler class[-]5
Energy class[-]B
PARAMETERSUNIT S.I.SEG EKO 26
Ecodesign[-]tak
Boiler class[-]5
Energy class[-]B
PARAMETERSUNIT S.I.SEG EKO 34
Ecodesign[-]tak
Boiler class[-]5
Energy class[-]B

SEG EKO

Boiler dimensions

TYPEUNIT S.I.SEG EKO 12
A[mm]1250
B1[mm]532
B2[mm]680
C1[mm]1160
C2[mm]
D1[mm]867
D2[mm]705
E[mm]707
F1[mm]907
F2[mm]213
F3[mm]349
F4[mm]213
G1[mm]180
G2[cal]1 1/2
G3[cal]1 1/2
G4[cal]3/4
H[mm]30
TYPEUNIT S.I.SEG EKO 15
A[mm]1250
B1[mm]532
B2[mm]680
C1[mm]1160
C2[mm]
D1[mm]867
D2[mm]705
E[mm]707
F1[mm]907
F2[mm]213
F3[mm]349
F4[mm]213
G1[mm]180
G2[cal]1 1/2
G3[cal]1 1/2
G4[cal]3/4
H[mm]30
TYPEUNIT S.I.SEG EKO 20
A[mm]1250
B1[mm]532
B2[mm]680
C1[mm]1356
C2[mm]
D1[mm]905
D2[mm]745
E[mm]720
F1[mm]1104
F2[mm]247
F3[mm]359
F4[mm]207
G1[mm]180
G2[cal]1 1/2
G3[cal]1 1/2
G4[cal]3/4
H[mm]30
TYPEUNIT S.I.SEG EKO 26
A[mm]1250
B1[mm]532
B2[mm]680
C1[mm]1413
C2[mm]
D1[mm]955
D2[mm]796
E[mm]776
F1[mm]1160
F2[mm]245
F3[mm]409
F4[mm]205
G1[mm]180
G2[cal]1 1/2
G3[cal]1 1/2
G4[cal]3/4
H[mm]30
TYPEUNIT S.I.SEG EKO 34
A[mm]1300
B1[mm]582
B2[mm]680
C1[mm]1413
C2[mm]
D1[mm]955
D2[mm]796
E[mm]776
F1[mm]1160
F2[mm]245
F3[mm]409
F4[mm]205
G1[mm]180
G2[cal]1 1/2
G3[cal]1 1/2
G4[cal]3/4
H[mm]30

SEG EKO

Boiler documentation

Z

DTR instructions

Technical and operational documentation for SEG EKO boiler
Z

Controller's manual

PLATINUM controller manual
Z

Energy label

Energy class B
Z

Eco Design Certificate

Z

Class 5 certificate

Boiler compliant with the requirements of PN-EN 303-5:2012 standard

Request for proposal

CONTACT

Consent required

9 + 11 =

The Metal-fach Jacek Kucharewicz company reserves the right to introduce changes in technical parameters, equipment and specifications of the offered goods without prior notice.