fbpx

BOILER

SEG BIO

Essential information

The SEG BIO boiler utilizes reliable technological and design solutions, making it an exceptionally efficient and proven source of heat. The boiler is designed for efficient burning of wood pellets in accordance with the norm 303-5:2021-09. It is equipped with a self-cleaning burner. The pellet igniter, in collaboration with an RTC clock, ignites and extinguishes the boiler according to a schedule, reducing the number of tasks required to operate the boiler to almost zero. With the option to add the ecoNET300 internet module to the boiler, you can manage the boiler’s functions from your phone, tablet, or computer.
Z
Available powers: 15kW | 20kW | 30kW | 40kW | 50kW | 75kW
Z
Fuel: Pellets
Z
Certificates: EcoDesign | 5 class
Z
Energy class: A +

Key benefits

Z

Heat exchanger

Horizontal and vertical convection channels | shelf
Efficient design adapted to quickly clean the exchanger on the front and top. The design of the boiler exchanger ensures high heat removal from the furnace.
Z

Flue outlet

At the back of the boiler
The structure of the boiler has been designed in such a way that the flue outlet is at the rear. The use of such a solution in a central heating boiler allows the flue to be directly led out to the chimney.
Z

Limit switch

For your safety, the boiler is equipped with a limit switch. The end protection system is placed in the boiler door and the tank flap. Each opening of the door or the flap causes the burner and other elements of the boiler to stop working automatically until they are closed again.
Z

Firefighter

It protects the fuel in the boiler container against ignition.
Z

Automatic feeder

The PLATINUM controller, on the basis of information received from sensors, determines the demand for fuel and doses it the right amount. The process of fuel combustion itself is therefore very economical, ecological and does not require additional service on the part of the user.
Z

Swirlers

The swirlers installed in the convection channels effectively reduce the speed of the exhaust gas outlet while maintaining high heat reception through the water jacket.

Boiler control

Adjust the boiler operation and room temperature to your individual needs. The PLATINUM PELLET controller is programmed in such a way as to automate all processes related to the heating of your home. The owner specifies the temperature he wants to have in the apartment, and the controller will optimize combustion in this respect. Entering the advanced driver settings, you can personalize each parameter. It all depends on the preferences of the user and household members!

Key features:

E
One CH.1 mixing circuit with room thermostat
E
Pump (DHW, CH, additional)
E
RTC clock with weekly timer
E
Weather control
E
Winter / summer operation mode
E
FuzzyLogic & PID

Optional equipment:

E
ecoNET 300 internet module
Control the work, monitor, compare the statistics thanks to the connection of the boiler controller with the internet module. Gain access to boiler control from a mobile phone, tablet or computer. The internet module is not only a remote control, it also records and registers the course of heating the house. Thanks to the ecoNET internet module (wired, wi-fi) you can gain control over your expenses and nothing will surprise you anymore!
E
Lambda probe
E
PLATINUM TOUCH room thermostat (touch, wired)
E
PLATINUM TOUCH x40 room thermostat (analog, wireless)
E
PLATINUM TOUCH x80 room thermostat (touch, wireless)
E
Platinum B module (buffer operation control, additional two heating circuits, 2x pump, 2x mixer, 2x thermostat)
E
Platinum C module (two additional heating circuits, 2x pump, 2x mixer, 2x thermostat)

Pellet burner

Gutter burner – for pellets

These are one of the most popular pellet burners on the market. The burner is equipped with an automatic ceramic pellet igniter, which allows it to be quickly ignited and extinguished. The design of the burner allows you to quickly reach a high temperature of the boiler. All functions of firing up the furnace and fuel dosage can be set in accordance with the current needs of the user.

Key features:

E
Fuel: Pellet
Ecological fuel such as pellets, also known as biomass, is produced by pressing wood waste such as sawdust or shavings. This completely natural fuel turns into biodegradable ash after burning.
E
Ceramic pellet lighter
Forget about manual boiler lighting. One click is enough and the automatic ceramic igniter ignites the fuel fed to the burner. Automatic igniter in conjunction with the RTC clock allows you to program the entire week of operation of the device. The device operation clock can be set separately for SUMMER and WINTER mode.

Technical data of the boiler

PARAMETERS UNIT S.I. SEG BIO 15
Nominal thermal power [kW] 15
Boiler power range [kW] 4,5-15
Heatable surface* [m2] 67,5-225
Water capacity [L] 60
Maximum working pressure [bar] 3
Maximum working temperaturea [°C] 80
Test pressure [bar] 4,5
Fuel tank capacity [L] 190
Fuel tank capacity [kg] 114
Fuel [-] pellets Φ6-8mm
Electrical connection [-] 5A; ~230V; 50Hz
Electric power consumption [W] 300
Temperature controller setting range [°C] 60-80 (every 1°C)
Chimney draft required [Pa] 20
Boiler weight [kg] 396

* A new building with very good thermal insulation was adopted for the calculations.

PARAMETERS UNIT S.I. SEG BIO 20
Nominal thermal power [kW] 20
Boiler power range [kW] 6-20
Heatable surface* [m2] 90-300
Water capacity [L] 68
Maximum working pressure [bar] 3
Maximum working temperature [°C] 80
Test pressure [bar] 4,5
Fuel tank capacity [L] 290
Fuel tank capacity [kg] 174
Fuel [-] pellets Φ6-8mm
Electrical connection [-] 5A; ~230V; 50Hz
Electric power consumption [W] 300
Temperature controller setting range [°C] 60-80 (every 1°C)
Chimney draft required [Pa] 23
Boiler weight [kg] 474

* A new building with very good thermal insulation was adopted for the calculations.

PARAMETERS UNIT S.I. SEG BIO 30
Nominal thermal power [kW] 30
Boiler power range [kW] 9-30
Heatable surface* [m2] 135-450
Water capacity [L] 73
Maximum working pressure [bar] 3
Maximum working temperature [°C] 80
Test pressure [bar] 4,5
Fuel tank capacity [L] 350
Fuel tank capacity [kg] 210
Fuel [-] pellets Φ6-8mm
Electrical connection [-] 5A; ~230V; 50Hz
Electric power consumption [W] 300
Temperature controller setting range [°C] 60-80 (every 1°C)
Chimney draft required [Pa] 23
Boiler weight [kg] 510

* A new building with very good thermal insulation was adopted for the calculations.

PARAMETERS UNIT S.I. SEG BIO 40
Nominal thermal power [kW] 40
Boiler power range [kW] 12-40
Heatable surface* [m2] 180-600
Water capacity [L] 95
Maximum working pressure [bar] 3
Maximum working temperature [°C] 80
Test pressure [bar] 4,5
Fuel tank capacity [L] 350
Fuel tank capacity [kg] 210
Fuel [-] pellets Φ6-8mm
Electrical connection [-] 5A; ~230V; 50Hz
Electric power consumption [W] 300
Temperature controller setting range [°C] 60-80 (every 1°C)
Chimney draft required [Pa] 35
Boiler weight [kg] 530

* A new building with very good thermal insulation was adopted for the calculations.

PARAMETERS UNIT S.I. SEG BIO 50
Nominal thermal power [kW] 50
Boiler power range [kW] 15-50
Heatable surface* [m2] 225-750
Water capacity [L] 120
Maximum working pressure [bar] 3
Maximum working temperature [°C] 80
Test pressure [bar] 4,5
Fuel tank capacity [L] 400
Fuel tank capacity [kg] 240
Fuel [-] pellets Φ6-8mm
Electrical connection [-] 5A; ~230V; 50Hz
Electric power consumption [W] 400
Temperature controller setting range [°C] 60-80 (every 1°C)
Chimney draft required [Pa] 38
Boiler weight [kg] 725

* A new building with very good thermal insulation was adopted for the calculations.

PARAMETERS UNIT S.I. SEG BIO 75
Nominal thermal power [kW] 75
Boiler power range [kW] 22,5-75
Heatable surface* [m2] 337,5-1125
Water capacity [L] 173
Maximum working pressure [bar] 3
Maximum working temperature [°C] 80
Test pressure [bar] 4,5
Fuel tank capacity [L] 520
Fuel tank capacity [kg] 312
Fuel [-] pellets Φ6-8mm
Electrical connection [-] 5A; ~230V; 50Hz
Electric power consumption [W] 400
Temperature controller setting range [°C] 60-80 (every 1°C)
Chimney draft required [Pa] 40
Boiler weight [kg] 855

* A new building with very good thermal insulation was adopted for the calculations.

Certificates, class, boiler emission

PARAMETERS UNIT S.I. SEG BIO 15
Ecodesign [-] tak
Boiler class [-] 5
Energy class [-] A+
Seasonal particulate emissions [mg/m3] 19
Efficiency for nominal power [%] 90,76
Nominal emissivity of the particulate matter [mg/m3] 19,5
Efficiency at minimum power [%] 89,38
Minimum emissivity of particulate matter [mg/m3] 19
PARAMETERS UNIT S.I. SEG BIO 20
Ecodesign [-] Yes
Boiler class [-] 5
Energy class [-] A+
Seasonal particulate emissions [mg/m3] 19
Efficiency for nominal power [%] 91,32
Nominal emissivity of the particulate matter [mg/m3] 18,4
Efficiency at minimum power [%] 89,85
Minimum emissivity of particulate matter [mg/m3] 19,3
PARAMETERS UNIT S.I. SEG BIO 30
Ecodesign [-] Yes
Boiler class [-] 5
Energy class [-] A+
Seasonal particulate emissions [mg/m3] 19
Efficiency for nominal power [%] 91,46
Nominal emissivity of the particulate matter [mg/m3] 18,7
Efficiency at minimum power [%] 90,22
Minimum emissivity of particulate matter [mg/m3] 19,3
PARAMETERS UNIT S.I. SEG BIO 40
Ecodesign [-] Yes
Boiler class [-] 5
Energy class [-] A+
Seasonal particulate emissions [mg/m3] 19
Efficiency for nominal power [%] 91,86
Nominal emissivity of the particulate matter [mg/m3] 18,8
Efficiency at minimum power [%] 90,61
Minimum emissivity of particulate matter [mg/m3] 19,4
PARAMETERS UNIT S.I. SEG BIO 50
Ecodesign [-] Yes
Boiler class [-] 5
Energy class [-] A+
Seasonal particulate emissions [mg/m3] 19
Efficiency for nominal power [%] 92,22
Nominal emissivity of the particulate matter [mg/m3] 18,8
Efficiency at minimum power [%] 90,94
Minimum emissivity of particulate matter [mg/m3] 19,5
PARAMETERS UNIT S.I. SEG BIO 75
Ecodesign [-] Yes
Boiler class [-] 5
Energy class [-] A+
Seasonal particulate emissions [mg/m3] 19
Efficiency for nominal power [%] 93,10
Nominal emissivity of the particulate matter [mg/m3] 18,9
Efficiency at minimum power [%] 91,82
Minimum emissivity of particulate matter [mg/m3] 19,5

Boiler dimensions

DIMENSION UNIT S.I. SEG BIO 15
A [mm] 1256
B1 [mm] 535
B2 [mm] 680
C1 [mm] 1160
C2 [mm] 1130
D1 [mm] 870
D2 [mm] 705
E [mm] 707
F1 [mm] 910
F2 [mm] 213
F3 [mm] 213
F4 [mm] 350
G1 [mm] 180
G2 [cal] 1 1/2
G3 [cal] 3/4
G4 [cal] 1 1/2
H [mm] 30
DIMENSION UNIT S.I. SEG BIO 20
A [mm] 1256
B1 [mm] 535
B2 [mm] 680
C1 [mm] 1355
C2 [mm] 1325
D1 [mm] 905
D2 [mm] 745
E [mm] 720
F1 [mm] 1105
F2 [mm] 247
F3 [mm] 207
F4 [mm] 360
G1 [mm] 180
G2 [cal] 1 1/2
G3 [cal] 3/4
G4 [cal] 1 1/2
H [mm] 30
DIMENSION UNIT S.I. SEG BIO 30
A [mm] 1256
B1 [mm] 535
B2 [mm] 680
C1 [mm] 1415
C2 [mm] 1385
D1 [mm] 955
D2 [mm] 795
E [mm] 776
F1 [mm] 1160
F2 [mm] 245
F3 [mm] 205
F4 [mm] 410
G1 [mm] 180
G2 [cal] 1 1/2
G3 [cal] 3/4
G4 [cal] 1 1/2
H [mm] 30
DIMENSION UNIT S.I. SEG BIO 40
A [mm] 1306
B1 [mm] 585
B2 [mm] 680
C1 [mm] 1415
C2 [mm] 1385
D1 [mm] 955
D2 [mm] 795
E [mm] 766
F1 [mm] 1160
F2 [mm] 245
F3 [mm] 205
F4 [mm] 410
G1 [mm] 180
G2 [cal] 1 1/2
G3 [cal] 3/4
G4 [cal] 1 1/2
H [mm] 30
DIMENSION UNIT S.I. SEG BIO 50
A [mm] 1406
B1 [mm] 682
B2 [mm] 680
C1 [mm] 1484
C2 [mm] 1454
D1 [mm] 1218
D2 [mm] 1003
E [mm] 850
F1 [mm] 1110
F2 [mm] 337
F3 [mm] 190
F4 [mm] 535
G1 [mm] 220
G2 [cal] 1 1/2
G3 [cal] 3/4
G4 [cal] 1 1/2
H [mm] 30
DIMENSION UNIT S.I. SEG BIO 75
A [mm] 1505
B1 [mm] 793
B2 [mm] 680
C1 [mm] 1520
C2 [mm] 1490
D1 [mm] 1413
D2 [mm] 1175
E [mm] 1075
F1 [mm] 1115
F2 [mm] 350
F3 [mm] 175
F4 [mm] 545
G1 [mm] 220
G2 [cal] 1 1/2
G3 [cal] 3/4
G4 [cal] 1 1/2
H [mm] 30

Boiler documentation

DTR instruction

Technical and operational documentation for the SEG BIO boiler Download

Driver manual

PLATIUM PELLET controller manual Download

EcoDesign certificate

The boiler complies with the requirements of the EcoDesign standard (EkoProjekt) – SEG BIO 15 Download
The boiler complies with the requirements of the EcoDesign standard (EkoProjekt) – SEG BIO 20 Download
The boiler complies with the requirements of the EcoDesign standard (EkoProjekt) – SEG BIO 30 Download
The boiler complies with the requirements of the EcoDesign standard (EkoProjekt) – SEG BIO 40 Download
The boiler complies with the requirements of the EcoDesign standard (EkoProjekt) – SEG BIO 50 Download
The boiler complies with the requirements of the EcoDesign standard (EkoProjekt) – SEG BIO 75 Download

Energy label

“A+” energy class – SEG BIO 15 Download
“A+” energy class – SEG BIO 20 Download
“A+” energy class – SEG BIO 30 Download
“A+” energy class – SEG BIO 40 Download
“A+” energy class – SEG BIO 50 Download
“A+” energy class – SEG BIO 75 Download

Product sheet in accordance with EU regulation 2015/1187

According to EU Regulation 2015/1187 supplementing Directive 2009/125 / EC of the European Parliament and of the Council Download

Product sheet in accordance with EU regulation 2015/1189

Compliant with the EU Commission Regulation 2015/1189 of April 28, 2015 – SEG BIO 15 Download
Compliant with the EU Commission Regulation 2015/1189 of April 28, 2015 – SEG BIO 20 Download
Compliant with the EU Commission Regulation 2015/1189 of April 28, 2015 – SEG BIO 30 Download
Compliant with the EU Commission Regulation 2015/1189 of April 28, 2015 – SEG BIO 40 Download
Compliant with the EU Commission Regulation 2015/1189 of April 28, 2015 – SEG BIO 50 Download
Compliant with the EU Commission Regulation 2015/1189 of April 28, 2015 – SEG BIO 75 Download

Foreign sales

Do you have a question about your future central heating boiler?

Paweł Czepiel

Export manager
Language: Russian, English
Monday-Friday (7:00 a.m. – 3:00 p.m.)

Phone:

+48 663 45 32 22
+48 85 711 94 54 ext. 17

E-mail:

p.czepiel@metalfach.com.pl

METAL-FACH Technika Grzewcza Sp. z o.o. reserves the right to introduce changes to the technical parameters, equipment and specifications of the offered goods without prior notice.

General contact:

Opening hours:

  • Mon.-Fri. 7:00a.m.-3:00p.m.
  • Phone: +48 85 711 94 54 int. 17
  • E-mail: p.czepiel@metalfach.com.pl

General contact:

Service contact:

Opening hours:

  • Mon.-Fri. 7:00a.m.–3:00 p.m.
  • Phone: +48 85 711 94 54 int. 17
  • E-mail: p.czepiel@metalfach.com.pl

Address data:

METAL-FACH Technika Grzewcza
Sp. z o.o.

  • st. Sikorskiego 66, 16-100 Sokółka, Poland
  • NIP: 545-182-60-12
  • REGON: 523566030

How to get: