General information

Technical data

Dimensions

Documentation

Z
Available powers: 60kW | 75kW | 95kW | 120kW | 150kW | 200kW | 250kW | 350kW
Z
Fuel: Firewood

General information

Economy meets convenience!

The SE boiler is an ideal solution dedicated to people who have a large supply of properly stored firewood or use ordinary coal. The operation of our device at nominal power allows for better use of fuel, and, as a result, also cleaner exhaust fumes into the atmosphere. Additionally, the boiler can be equipped with automatics regulating combustion and operation of the device.

Technology and security

Z

Heat exchanger

Horizontal convection channels | regimental
Effective structure adapted to the quick cleaning of the exchanger from the front. The design of the boiler exchanger ensures high heat removal from the furnace.
Z

Flue outlet

At the back of the boiler
The structure of the boiler has been designed in such a way that the flue outlet is at the rear. The use of such a solution in a central heating boiler allows the flue to be directly led out to the chimney.
Z

Secondary air damper

Air opening with regulation, which allows more accurate combustion of fuel particles floating in the combustion chamber.
Z

Blower fan

Optional accessories
Effectively supports the natural exhaust gas flow in the boiler. Additionally, it prevents smoke from escaping from the boiler to the boiler room. It also requires a driver to be installed.
Z

Draft regulator

Optional accessories

Depending on the temperature of the medium, it controls the flap regulating the air supply to the boiler combustion chamber.

Connectivity and functionality

Optional accessories

Simple boiler control

Adjust the boiler operation and room temperature to your individual needs. The DK SYSTEM-420 controller is programmed in such a way as to automate partially the processes related to heating your home. The owner specifies the temperature he wants to have in the room, and the controller will optimize combustion in this respect.

Key Features:

E
Pump (DHW, C.H.1)
E
Room thermostat
E
WINTER / SUMMER operation mode

Manual firing up

Manual ignition and fuel loading

We can load firewood or coal into the combustion chamber. Wood, unlike coal, properly seasoned is an ecological fuel that meets all standards. It is completely natural, as a result of combustion, biodegradable ash is produced. By burning properly seasoned wood, we produce a small amount of harmful compounds into the atmosphere.

Technical data of the boiler

PARAMETERS S.I. UNIT SE 60
Nominal heat output[kW]60
Range of boiler power[kW]60
Area that can be heated *[m2]600-900
Heating area[m2]3,4
Water capacity[L]90
Maximum working pressure[bar]3
Maximum operating temperature[°C]85
Test pressure[bar]4.5
Fuel[-]wood, coal
Chimney draft required[Pa]
Boiler weight[kg]438

* A new building with very good thermal insulation was assumed for the calculations.

PARAMETERS S.I. UNIT SE 75
Nominal heat output[kW]75
Range of boiler power[kW]75
Area that can be heated *[m2]750-1125
Heating area[m2]3.8
Water capacity[L]105
Maximum working pressure[bar]3
Maximum operating temperature[°C]85
Test pressure[bar]4.5
Fuel[-]wood, coal
Chimney draft required[Pa]
Boiler weight[kg]480

* A new building with very good thermal insulation was assumed for the calculations.

PARAMETERS S.I. UNIT SE 95
Nominal heat output[kW]95
Range of boiler power[kW]95
Area that can be heated *[m2]950-1425
Heating area[m2]4.5
Water capacity[L]115
Maximum working pressure[bar]3
Maximum operating temperature[°C]85
Test pressure[bar]4.5
Fuel[-]wood, coal
Chimney draft required[Pa]
Boiler weight[kg]521

* A new building with very good thermal insulation was assumed for the calculations.

PARAMETERS S.I. UNIT SE 120
Nominal heat output[kW]120
Range of boiler power[kW]120
Area that can be heated *[m2]1200-1800
Heating area[m2]6.9
Water capacity[L]260
Maximum working pressure[bar]3
Maximum operating temperature[°C]85
Test pressure[bar]4.5
Fuel[-]wood, coal
Chimney draft required[Pa]
Boiler weight[kg]850

* A new building with very good thermal insulation was assumed for the calculations.

PARAMETERS S.I. UNIT SE 150
Nominal heat output[kW]150
Range of boiler power[kW]150
Area that can be heated *[m2]1500-2250
Heating area[m2]8.0
Water capacity[L]316
Maximum working pressure[bar]3
Maximum operating temperature[°C]85
Test pressure[bar]4.5
Fuel[-]wood, coal
Chimney draft required[Pa]
Boiler weight[kg]1015

* A new building with very good thermal insulation was assumed for the calculations.

PARAMETERS S.I. UNIT SE 200
Nominal heat output[kW]200
Range of boiler power[kW]200
Area that can be heated *[m2]2000-3000
Heating area[m2]9.2
Water capacity[L]316
Maximum working pressure[bar]3
Maximum operating temperature[°C]85
Test pressure[bar]4.5
Fuel[-]wood, coal
Chimney draft required[Pa]
Boiler weight[kg]1090

* A new building with very good thermal insulation was assumed for the calculations.

PARAMETERS S.I. UNIT SE 250
Nominal heat output[kW]250
Range of boiler power[kW]250
Area that can be heated *[m2]2500-3750
Heating area[m2]10
Water capacity[L]330
Maximum working pressure[bar]3
Maximum operating temperature[°C]85
Test pressure[bar]4.5
Fuel[-]wood, coal
Chimney draft required[Pa]
Boiler weight[kg]1160

* A new building with very good thermal insulation was assumed for the calculations.

PARAMETERS S.I. UNIT SE 350
Nominal heat output[kW]350
Range of boiler power[kW]350
Area that can be heated *[m2]3500-5250
Heating area[m2]18.32
Water capacity[L]713
Maximum working pressure[bar]3
Maximum operating temperature[°C]85
Test pressure[bar]4.5
Fuel[-]wood, coal
Chimney draft required[Pa]
Boiler weight[kg]2050

* A new building with very good thermal insulation was assumed for the calculations.

Boiler dimensions

TYPE S.I. UNIT SE 60
A[mm]530
B1[mm]
B2[mm]
C1[mm]1530
C2[mm]
D1[mm]960
D2[mm]800
E[mm]
F1[mm]1330
F2[mm]225
F3[mm]584
F4[mm]175
G1[mm]200
G2[cal]1 1/2
G3[cal]1 1/2
G4[cal]3/4
H[mm]30
TYPE S.I. UNIT SE 75
A[mm]580
B1[mm]
B2[mm]
C1[mm]1530
C2[mm]
D1[mm]960
D2[mm]800
E[mm]
F1[mm]1330
F2[mm]225
F3[mm]584
F4[mm]175
G1[mm]200
G2[cal]1 1/2
G3[cal]1 1/2
G4[cal]3/4
H[mm]30
TYPE S.I. UNIT SE 95
A[mm]680
B1[mm]
B2[mm]
C1[mm]1530
C2[mm]
D1[mm]960
D2[mm]800
E[mm]
F1[mm]1330
F2[mm]225
F3[mm]584
F4[mm]185
G1[mm]200
G2[cal]1 1/2
G3[cal]1 1/2
G4[cal]3/4
H[mm]30
TYPE S.I. UNIT SE 120
A[mm]770
B1[mm]
B2[mm]
C1[mm]1830
C2[mm]
D1[mm]1550
D2[mm]1120
E[mm]
F1[mm]1690
F2[mm]195
F3[mm]480
F4[mm]100
G1[mm]250
G2[cal]2
G3[cal]2
G4[cal]3/4
H[mm]30
TYPE S.I. UNIT SE 150
A[mm]860
B1[mm]
B2[mm]
C1[mm]1910
C2[mm]
D1[mm]1580
D2[mm]1170
E[mm]
F1[mm]1780
F2[mm]180
F3[mm]660
F4[mm]155
G1[mm]250
G2[cal]2
G3[cal]2
G4[cal]3/4
H[mm]30
TYPE S.I. UNIT SE 200
A[mm]860
B1[mm]
B2[mm]
C1[mm]2110
C2[mm]
D1[mm]1580
D2[mm]1170
E[mm]
F1[mm]1980
F2[mm]180
F3[mm]655
F4[mm]155
G1[mm]250
G2[cal]2
G3[cal]2
G4[cal]3/4
H[mm]30
TYPE S.I. UNIT SE 250
A[mm]860
B1[mm]
B2[mm]
C1[mm]2110
C2[mm]
D1[mm]1580
D2[mm]1270
E[mm]
F1[mm]1980
F2[mm]180
F3[mm]655
F4[mm]155
G1[mm]250
G2[cal]2
G3[cal]2
G4[cal]3/4
H[mm]30
TYPE S.I. UNIT SE 350
A[mm]1202
B1[mm]
B2[mm]
C1[mm]2030
C2[mm]
D1[mm]2230
D2[mm]1726
E[mm]
F1[mm]1553
F2[mm]382
F3[mm]711
F4[mm]344
G1[mm]350
G2[mm]101,6
G3[mm]101,6
G4[cal]1 1/4
H[mm]30

Boiler documentation

Z

DTR statement

Technical and operational documentation for SE boiler

Z

Driver manual

DK SYSTEM-420 controller manual

Contact us

Contact form

Type of fuel

Consent required

13 + 1 =

Paweł Czepiel

Export manager
Language: Russian, English
Phone. +48 85 711 94 54 ext. 17
Mobile: +48 663 45 32 22
E-mail: p.czepiel@metalfach.com.pl
Monday-Friday (from 7:00 a.m. to 3:00 p.m.)

Metal-fach Jacek Kucharewicz reserves the right to introduce changes to the technical parameters, equipment and specifications of the offered goods without prior notice. The information contained does not constitute an assurance within the meaning of Art. 4 sec. 3 and 4 of the Act of 27.07.2002. on the specific conditions of consumer sale and on the amendment to the Civil Code (hereinafter the “Act”), and do not constitute a description of the goods within the meaning of Art. 4 sec. 2 of the Act. The guide does not constitute an offer within the meaning of Art. 66 of the Civil Code.

General contact:

Opening hours:

  • Monday-Friday (7:00 a.m. – 3:00 p.m.)
  • Phone: +48 85 711 94 54 int. 17
  • E-mail: p.czepiel@metalfach.com.pl

Social Media:

Service contact:

Opening hours:

  • Monday-Friday (7:00 a.m. – 3:00 p.m.)
  • Phone: +48 85 711 94 54 int. 17
  • E-mail: p.czepiel@metalfach.com.pl

Address data:

METAL-FACH Jacek Kucharewicz

  • 16-100 Sokółka st. Sikorskiego 66
  • NIP: 545-100-10-62
  • REGON: 050073833

How to get: