BOILER
GRAND PELLET
Essential Information
Key benefits
Heat exchanger
Effective structure adapted to automatic cleaning of the exchanger. The design of the boiler exchanger ensures high heat removal from the furnace.
Flue outlet
The structure of the boiler has been designed in such a way that the flue outlet is at the rear. The use of such a solution in a central heating boiler allows the flue to be directly led out to the chimney.
Limit switch
Exhaust fan
The exhaust fan effectively supports the natural flue gas draft in the boiler.
Steel screens
Automatic feeder
Automatic ash removal system
Swirlers
Swirlers installed in the convection channels, connected with the automatic cleaning system, effectively reduce the speed of the exhaust gas outlet. Thanks to systematic cleaning, the boiler maintains a constant high heat consumption through the water jacket. The use of automatic cleaning of convection channels contributes to the reduction of fuel consumption.
Boiler control
Key features:
Standard equipment:
Control the work, monitor, compare statistics thanks to the connection of the boiler controller with the internet module. Gain access to boiler control from a mobile phone, tablet or computer. The internet module is not only a remote control, it also records and registers the course of heating the house. Thanks to the ecoNET internet module (wired, wi-fi) you can gain control over your expenses and nothing will surprise you anymore!
Optional equipment:
Pellet burner
Self-cleaning PPW burner – for pellets
Quick firing up of the furnace and automatic cleaning of the furnace of ash. The burner is equipped with an automatic ceramic pellet igniter and has been designed for regular, automatic cleaning of ash. The design of the burner allows you to quickly reach a high temperature of the boiler. All functions of cleaning the furnace from ash and fuel dosage can be set in accordance with the current needs of the user.
Key features:
Ecological fuel such as pellets, also known as biomass, is produced by pressing wood waste such as sawdust or shavings. This completely natural fuel turns into biodegradable ash after burning.
(100,150 kW – two automatic ceramic igniters)
Forget about manual boiler lighting. One click is enough and the automatic ceramic igniter ignites the fuel fed to the burner. Automatic igniter in conjunction with the RTC clock allows you to program the entire week of operation of the device. The device operation clock can be set separately for SUMMER and WINTER mode.
The burner is cleaned of ash on its own on a regular basis, which reduces the need for manual cleaning to a minimum. The use of this technology prevents clogging of the furnace chamber with ash, and also allows the burner to be kept in excellent efficiency.
Technical data of the boiler
PARAMETERS | UNIT S.I. | GRAND PELLET 50 |
Nominal thermal power | [kW] | 50 |
Boiler power range | [kW] | 15-50 |
Heatable surface* | [m2] | 225-750 |
Water capacity | [L] | 245 |
Maximum working pressure | [bar] | 3 |
Maximum working temperature | [°C] | 80 |
Test pressure | [bar] | 4,5 |
Fuel tank capacity | [L] | 1000 |
Fuel tank capacity | [kg] | 600 |
Fuel | [-] | pellets Φ6-8mm |
Electrical connection | [-] | 4,0A;~230V; 50Hz |
Electric power consumption | [W] | 300 |
Temperature controller setting range | [°C] | 60-80 (every 1°C) |
Chimney draft required | [Pa] | 33 |
Boiler weight | [kg] | 880 |
* A new building with very good thermal insulation was adopted for the calculations.
PARAMETERS | UNIT S.I. | GRAND PELLET 75 |
Nominal thermal power | [kW] | 75 |
Boiler power range | [kW] | 22,5-75 |
Heatable surface* | [m2] | 337,5-1125 |
Water capacity | [L] | 245 |
Maximum working pressure | [bar] | 3 |
Maximum working temperature | [°C] | 80 |
Test pressure | [bar] | 4,5 |
Fuel tank capacity | [L] | 1000 |
Fuel tank capacity | [kg] | 600 |
Fuel | [-] | pellets Φ6-8mm |
Electrical connection | [-] | 3,2A; ~230V; 50Hz |
Electric power consumption | [W] | 300 |
Temperature controller setting range | [°C] | 60-80 (every 1°C) |
Chimney draft required | [Pa] | 38 |
Boiler weight | [kg] | 880 |
* A new building with very good thermal insulation was adopted for the calculations.
PARAMETERS | UNIT S.I. | GRAND PELLET 100 |
Nominal thermal power | [kW] | 100 |
Boiler power range | [kW] | 30-100 |
Heatable surface* | [m2] | 450-1500 |
Water capacity | [L] | 360 |
Maximum working pressure | [bar] | 3 |
Maximum working temperature | [°C] | 80 |
Test pressure | [bar] | 4,5 |
Fuel tank capacity | [L] | 1000 |
Fuel tank capacity | [kg] | 600 |
Fuel | [-] | pellets Φ6-8mm |
Electrical connection | [-] | 4,5A; ~230V; 50Hz |
Electric power consumption | [W] | 320 |
Temperature controller setting range | [°C] | 60-80 (every 1°C) |
Chimney draft required | [Pa] | 40 |
Boiler weight | [kg] | 1095 |
* A new building with very good thermal insulation was adopted for the calculations.
PARAMETERS | UNIT S.I. | GRAND PELLET 150 |
Nominal thermal power | [kW] | 150 |
Boiler power range | [kW] | 45-150 |
Heatable surface* | [m2] | 675-2250 |
Water capacity | [L] | 360 |
Maximum working pressure | [bar] | 3 |
Maximum working temperature | [°C] | 80 |
Test pressure | [bar] | 4,5 |
Fuel tank capacity | [L] | 1000 |
Fuel tank capacity | [kg] | 600 |
Fuel | [-] | pellets Φ6-8mm |
Electrical connection | [-] | 4,5A; ~230V; 50Hz |
Electric power consumption | [W] | 320 |
Temperature controller setting range | [°C] | 60-80 (every 1°C) |
Chimney draft required | [Pa] | 44 |
Boiler weight | [kg] | 1125 |
* A new building with very good thermal insulation was adopted for the calculations.
Certificates, class, boiler emission
PARAMETERS | UNIT S.I. | GRAND PELLET 50 |
Ecodesign | [-] | Yes |
Boiler class | [-] | 5 |
Energy class | [-] | A+ |
Seasonal particulate emissions | [mg/m3] | 13,87 |
Efficiency for nominal power | [%] | 92,82 |
Nominal emissivity of the particulate matter | [mg/m3] | 10,04 |
Efficiency at minimum power | [%] | 93,09 |
Minimum emissivity of particulate matter | [mg/m3] | 14,54 |
PARAMETERS | UNIT S.I. | GRAND PELLET 75 |
Ecodesign | [-] | Yes |
Boiler class | [-] | 5 |
Energy class | [-] | A+ |
Seasonal particulate emissions | [mg/m3] | 16,01 |
Efficiency for nominal power | [%] | 92,75 |
Nominal emissivity of the particulate matter | [mg/m3] | 12,15 |
Efficiency at minimum power | [%] | 92,93 |
Minimum emissivity of particulate matter | [mg/m3] | 16,69 |
PARAMETERS | UNIT S.I. | GRAND PELLET 100 |
Ecodesign | [-] | Yes |
Boiler class | [-] | 5 |
Energy class | [-] | A+ |
Seasonal particulate emissions | [mg/m3] | 13,14 |
Efficiency for nominal power | [%] | 92,83 |
Nominal emissivity of the particulate matter | [mg/m3] | 10,14 |
Efficiency at minimum power | [%] | 92,66 |
Minimum emissivity of particulate matter | [mg/m3] | 13,67 |
PARAMETERS | UNIT S.I. | GRAND PELLET 150 |
Ecodesign | [-] | Yes |
Boiler class | [-] | 5 |
Energy class | [-] | A+ |
Seasonal particulate emissions | [mg/m3] | 16,82 |
Efficiency for nominal power | [%] | 92,78 |
Nominal emissivity of the particulate matter | [mg/m3] | 11,64 |
Efficiency at minimum power | [%] | 92,93 |
Minimum emissivity of particulate matter | [mg/m3] | 17,73 |
Boiler dimensions
DIMENSION | UNIT S.I. | GRAND PELLET 50 |
A | [mm] | 2429 |
B1 | [mm] | 1255 |
B1′ | [mm] | 815 |
B2 | [mm] | 1111 |
C1 | [mm] | 1475 |
C2 | [mm] | 1636 |
D1 | [mm] | 2190 |
D2 | [mm] | 1450 |
E | [mm] | 1890 |
F1 | [mm] | 1015 |
F2 | [mm] | 970 |
F3 | [mm] | 1000 |
F4 | [mm] | 145 |
G1 | [mm] | 180 |
G2 | [cal] | 1 1/2 |
G3 | [cal] | 1 1/2 |
G4 | [cal] | 3/4 |
H | [mm] | – |
DIMENSION | UNIT S.I. | GRAND PELLET 75 |
A | [mm] | 2429 |
B1 | [mm] | 1255 |
B1′ | [mm] | 815 |
B2 | [mm] | 1111 |
C1 | [mm] | 1475 |
C2 | [mm] | 1636 |
D1 | [mm] | 2190 |
D2 | [mm] | 1450 |
E | [mm] | 1890 |
F1 | [mm] | 1015 |
F2 | [mm] | 970 |
F3 | [mm] | 1000 |
F4 | [mm] | 145 |
G1 | [mm] | 180 |
G2 | [cal] | 1 1/2 |
G3 | [cal] | 1 1/2 |
G4 | [cal] | 3/4 |
H | [mm] | – |
DIMENSION | UNIT S.I. | GRAND PELLET 100 |
A | [mm] | 2429 |
B1 | [mm] | 1255 |
B1′ | [mm] | 815 |
B2 | [mm] | 1111 |
C1 | [mm] | 1715 |
C2 | [mm] | 1636 |
D1 | [mm] | 2500 |
D2 | [mm] | 1600 |
E | [mm] | 2130 |
F1 | [mm] | 1345 |
F2 | [mm] | 1250 |
F3 | [mm] | 1140 |
F4 | [mm] | 145 |
G1 | [mm] | 185 |
G2 | [cal] | 1 1/2 |
G3 | [cal] | 1 1/2 |
G4 | [cal] | 3/4 |
H | [mm] | – |
DIMENSION | UNIT S.I. | GRAND PELLET 150 |
A | [mm] | 2429 |
B1 | [mm] | 1255 |
B1′ | [mm] | 815 |
B2 | [mm] | 1111 |
C1 | [mm] | 1715 |
C2 | [mm] | 1636 |
D1 | [mm] | 2600 |
D2 | [mm] | 1600 |
E | [mm] | 2230 |
F1 | [mm] | 1345 |
F2 | [mm] | 1250 |
F3 | [mm] | 1240 |
F4 | [mm] | 145 |
G1 | [mm] | 185 |
G2 | [cal] | 1 1/2 |
G3 | [cal] | 1 1/2 |
G4 | [cal] | 3/4 |
H | [mm] | – |
Boiler documentation
DTR instruction
Technical and operational documentation | Download |
Driver manual
PLATIUM PELLET controller manual | Download |
EcoDesign certificate
The boiler complies with the requirements of the EcoDesign standard (Eco Design) – 50 | Download |
The boiler complies with the requirements of the EcoDesign standard (Eco Design) – 75-150 – 10.2023 | Download |
The boiler complies with the requirements of the EcoDesign standard (Eco Design) – 70-150 – 11.2020 | Download |
Energy label
Product sheet in accordance with EU regulation 2015/1187
According to EU Regulation 2015/1187 supplementing Directive 2009/125 / EC of the European Parliament and of the Council | Download |
Product sheet in accordance with EU regulation 2015/1189
According to EU Regulation 2015/1189 supplementing Directive 2009/125 / EC of the European Parliament and of the Council – 50kW | Download |
According to EU Regulation 2015/1189 supplementing Directive 2009/125 / EC of the European Parliament and of the Council – 75kW | Download |
According to EU Regulation 2015/1189 supplementing Directive 2009/125 / EC of the European Parliament and of the Council – 100kW | Download |
According to EU Regulation 2015/1189 supplementing Directive 2009/125 / EC of the European Parliament and of the Council – 150kW | Download |
Foreign sales
Paweł Czepiel
Export manager
Language: Russian, English
Monday-Friday (7:00 a.m. – 3:00 p.m.)
Phone:
+48 663 45 32 22
+48 85 711 94 54 ext. 17
E-mail:
p.czepiel@metalfach.com.pl
General contact:
Opening hours:
- Mon.-Fri. 7:00a.m.-3:00p.m.
- Phone: +48 85 711 94 54 int. 17
- E-mail: p.czepiel@metalfach.com.pl
General contact:
Service contact:
Opening hours:
- Mon.-Fri. 7:00a.m.–3:00 p.m.
- Phone: +48 85 711 94 54 int. 17
- E-mail: p.czepiel@metalfach.com.pl
Address data:
METAL-FACH Technika Grzewcza
Sp. z o.o.
- st. Sikorskiego 66, 16-100 Sokółka, Poland
- NIP: 545-182-60-12
- REGON: 523566030