The GRAND PELLET boiler is the perfect solution for medium to large buildings and production halls. The boiler is designed for efficient burning of wood pellets in accordance with the norm 303-5:2021-09. It is equipped with a self-cleaning burner and a comprehensive self-cleaning system for the heat exchanger. The pellet igniter, in collaboration with an RTC clock, ignites and extinguishes the boiler according to a schedule, reducing the amount of tasks required to operate the boiler to almost zero. Thanks to the ecoNET300 internet module included with the boiler, you can manage the boiler’s functions from your phone, tablet, or computer.
Z
Available powers: 50kW | 75kW | 100kW | 150kW
Z
Fuel: Pellets
Z
Certificates: EcoDesign | 5 class
Z
Energy class: A +

Key benefits

Z

Heat exchanger

Vertical convection channels | tubular
Effective structure adapted to automatic cleaning of the exchanger. The design of the boiler exchanger ensures high heat removal from the furnace.
Z

Flue outlet

At the back of the boiler
The structure of the boiler has been designed in such a way that the flue outlet is at the rear. The use of such a solution in a central heating boiler allows the flue to be directly led out to the chimney.
Z

Limit switch

For the sake of your safety, the boiler is equipped with a limit switch. The end protection system is located in the boiler door. Each door opening automatically stops the operation of the burner and other elements of the boiler until they are closed again.
Z

Exhaust fan

Adjustable height
The exhaust fan effectively supports the natural flue gas draft in the boiler.
Z

Steel screens

The use of steel screens in the combustion chamber improves the efficiency of the combustion process. The screens increase the temperature in the combustion chamber and stop the particles floating above the furnace, burning them up. The thermal efficiency of the boiler increases, and the flue gas has a reduced amount of compounds harmful to the environment to a minimum.
Z

Automatic feeder

The PLATINUM PELLET controller, based on the information received from the sensors, determines the demand for fuel and doses it the right amount. The process of fuel combustion itself is therefore very economical, ecological and does not require additional service on the part of the user.
Z

Automatic ash removal system

The process of automatic ash removal consists in pushing the ash outside the boiler, into two specially designed containers. Both containers for collecting ash have wheels and a handle, thanks to which you can efficiently pull or lift them.
Z

Swirlers

Combined with automatic cleaning of convection channels
Swirlers installed in the convection channels, connected with the automatic cleaning system, effectively reduce the speed of the exhaust gas outlet. Thanks to systematic cleaning, the boiler maintains a constant high heat consumption through the water jacket. The use of automatic cleaning of convection channels contributes to the reduction of fuel consumption.

Boiler control

Adjust the boiler operation and room temperature to your individual needs. The PLATINUM PELLET controller is programmed in such a way as to automate all processes related to the heating of your home. The owner specifies the temperature he wants to have in the apartment, and the controller will optimize combustion in this respect. Entering the advanced driver settings, you can personalize each parameter. It all depends on the preferences of the user and household members!

Key features:

E
One CH.1 mixing circuit with room thermostat
E
Pump (DHW, CH, additional)
E
RTC clock with weekly timer
E
Weather control
E
Winter / summer operation mode
E
FuzzyLogic & PID

Standard equipment:

E
ecoNET 300 internet module
Control the work, monitor, compare statistics thanks to the connection of the boiler controller with the internet module. Gain access to boiler control from a mobile phone, tablet or computer. The internet module is not only a remote control, it also records and registers the course of heating the house. Thanks to the ecoNET internet module (wired, wi-fi) you can gain control over your expenses and nothing will surprise you anymore!

Optional equipment:

E
Lambda probe
E
PLATINUM TOUCH room thermostat (touchscreen, wired)
E
PLATINUM TOUCH x40 room thermostat (analog, wireless)
E
PLATINUM TOUCH x80 room thermostat (touch, wireless)
E
Platinum B module (buffer operation control, additional two heating circuits, 2x pump, 2x mixer, 2x thermostat)
E
Platinum C module (two additional heating circuits, 2x pump, 2x mixer, 2x thermostat)

Pellet burner

Self-cleaning PPW burner – for pellets

Quick firing up of the furnace and automatic cleaning of the furnace of ash. The burner is equipped with an automatic ceramic pellet igniter and has been designed for regular, automatic cleaning of ash. The design of the burner allows you to quickly reach a high temperature of the boiler. All functions of cleaning the furnace from ash and fuel dosage can be set in accordance with the current needs of the user.

Key features:

E
Fuel: Pellet
Ecological fuel such as pellets, also known as biomass, is produced by pressing wood waste such as sawdust or shavings. This completely natural fuel turns into biodegradable ash after burning.
E
(50.75 kW – one automatic ceramic igniter)
(100,150 kW – two automatic ceramic igniters)
Forget about manual boiler lighting. One click is enough and the automatic ceramic igniter ignites the fuel fed to the burner. Automatic igniter in conjunction with the RTC clock allows you to program the entire week of operation of the device. The device operation clock can be set separately for SUMMER and WINTER mode.
E
Automatic cleaning
The burner is cleaned of ash on its own on a regular basis, which reduces the need for manual cleaning to a minimum. The use of this technology prevents clogging of the furnace chamber with ash, and also allows the burner to be kept in excellent efficiency.

Technical data of the boiler

PARAMETERS UNIT S.I. GRAND PELLET 50
Nominal thermal power [kW] 50
Boiler power range [kW] 15-50
Heatable surface* [m2] 225-750
Water capacity [L] 245
Maximum working pressure [bar] 3
Maximum working temperature [°C] 80
Test pressure [bar] 4,5
Fuel tank capacity [L] 1000
Fuel tank capacity [kg] 600
Fuel [-] pellets Φ6-8mm
Electrical connection [-] 4,0A;~230V; 50Hz
Electric power consumption [W] 300
Temperature controller setting range [°C] 60-80 (every 1°C)
Chimney draft required [Pa] 33
Boiler weight [kg] 880

* A new building with very good thermal insulation was adopted for the calculations.

PARAMETERS UNIT S.I. GRAND PELLET 75
Nominal thermal power [kW] 75
Boiler power range [kW] 22,5-75
Heatable surface* [m2] 337,5-1125
Water capacity [L] 245
Maximum working pressure [bar] 3
Maximum working temperature [°C] 80
Test pressure [bar] 4,5
Fuel tank capacity [L] 1000
Fuel tank capacity [kg] 600
Fuel [-] pellets Φ6-8mm
Electrical connection [-] 3,2A; ~230V; 50Hz
Electric power consumption [W] 300
Temperature controller setting range [°C] 60-80 (every 1°C)
Chimney draft required [Pa] 38
Boiler weight [kg] 880

* A new building with very good thermal insulation was adopted for the calculations.

PARAMETERS UNIT S.I. GRAND PELLET 100
Nominal thermal power [kW] 100
Boiler power range [kW] 30-100
Heatable surface* [m2] 450-1500
Water capacity [L] 360
Maximum working pressure [bar] 3
Maximum working temperature [°C] 80
Test pressure [bar] 4,5
Fuel tank capacity [L] 1000
Fuel tank capacity [kg] 600
Fuel [-] pellets Φ6-8mm
Electrical connection [-] 4,5A; ~230V; 50Hz
Electric power consumption [W] 320
Temperature controller setting range [°C] 60-80 (every 1°C)
Chimney draft required [Pa] 40
Boiler weight [kg] 1095

* A new building with very good thermal insulation was adopted for the calculations.

PARAMETERS UNIT S.I. GRAND PELLET 150
Nominal thermal power [kW] 150
Boiler power range [kW] 45-150
Heatable surface* [m2] 675-2250
Water capacity [L] 360
Maximum working pressure [bar] 3
Maximum working temperature [°C] 80
Test pressure [bar] 4,5
Fuel tank capacity [L] 1000
Fuel tank capacity [kg] 600
Fuel [-] pellets Φ6-8mm
Electrical connection [-] 4,5A; ~230V; 50Hz
Electric power consumption [W] 320
Temperature controller setting range [°C] 60-80 (every 1°C)
Chimney draft required [Pa] 44
Boiler weight [kg] 1125

* A new building with very good thermal insulation was adopted for the calculations.

Certificates, class, boiler emission

PARAMETERS UNIT S.I. GRAND PELLET 50
Ecodesign [-] Yes
Boiler class [-] 5
Energy class [-] A+
Seasonal particulate emissions [mg/m3] 13,87
Efficiency for nominal power [%] 92,82
Nominal emissivity of the particulate matter [mg/m3] 10,04
Efficiency at minimum power [%] 93,09
Minimum emissivity of particulate matter [mg/m3] 14,54
PARAMETERS UNIT S.I. GRAND PELLET 75
Ecodesign [-] Yes
Boiler class [-] 5
Energy class [-] A+
Seasonal particulate emissions [mg/m3] 16,01
Efficiency for nominal power [%] 92,75
Nominal emissivity of the particulate matter [mg/m3] 12,15
Efficiency at minimum power [%] 92,93
Minimum emissivity of particulate matter [mg/m3] 16,69
PARAMETERS UNIT S.I. GRAND PELLET 100
Ecodesign [-] Yes
Boiler class [-] 5
Energy class [-] A+
Seasonal particulate emissions [mg/m3] 13,14
Efficiency for nominal power [%] 92,83
Nominal emissivity of the particulate matter [mg/m3] 10,14
Efficiency at minimum power [%] 92,66
Minimum emissivity of particulate matter [mg/m3] 13,67
PARAMETERS UNIT S.I. GRAND PELLET 150
Ecodesign [-] Yes
Boiler class [-] 5
Energy class [-] A+
Seasonal particulate emissions [mg/m3] 16,82
Efficiency for nominal power [%] 92,78
Nominal emissivity of the particulate matter [mg/m3] 11,64
Efficiency at minimum power [%] 92,93
Minimum emissivity of particulate matter [mg/m3] 17,73

Boiler dimensions

DIMENSION UNIT S.I. GRAND PELLET 50
A [mm] 2429
B1 [mm] 1255
B1′ [mm] 815
B2 [mm] 1111
C1 [mm] 1475
C2 [mm] 1636
D1 [mm] 2190
D2 [mm] 1450
E [mm] 1890
F1 [mm] 1015
F2 [mm] 970
F3 [mm] 1000
F4 [mm] 145
G1 [mm] 180
G2 [cal] 1 1/2
G3 [cal] 1 1/2
G4 [cal] 3/4
H [mm]
DIMENSION UNIT S.I. GRAND PELLET 75
A [mm] 2429
B1 [mm] 1255
B1′ [mm] 815
B2 [mm] 1111
C1 [mm] 1475
C2 [mm] 1636
D1 [mm] 2190
D2 [mm] 1450
E [mm] 1890
F1 [mm] 1015
F2 [mm] 970
F3 [mm] 1000
F4 [mm] 145
G1 [mm] 180
G2 [cal] 1 1/2
G3 [cal] 1 1/2
G4 [cal] 3/4
H [mm]
DIMENSION UNIT S.I. GRAND PELLET 100
A [mm] 2429
B1 [mm] 1255
B1′ [mm] 815
B2 [mm] 1111
C1 [mm] 1715
C2 [mm] 1636
D1 [mm] 2500
D2 [mm] 1600
E [mm] 2130
F1 [mm] 1345
F2 [mm] 1250
F3 [mm] 1140
F4 [mm] 145
G1 [mm] 185
G2 [cal] 1 1/2
G3 [cal] 1 1/2
G4 [cal] 3/4
H [mm]
DIMENSION UNIT S.I. GRAND PELLET 150
A [mm] 2429
B1 [mm] 1255
B1′ [mm] 815
B2 [mm] 1111
C1 [mm] 1715
C2 [mm] 1636
D1 [mm] 2600
D2 [mm] 1600
E [mm] 2230
F1 [mm] 1345
F2 [mm] 1250
F3 [mm] 1240
F4 [mm] 145
G1 [mm] 185
G2 [cal] 1 1/2
G3 [cal] 1 1/2
G4 [cal] 3/4
H [mm]

Boiler documentation

DTR instruction

Technical and operational documentation Download

Driver manual

PLATIUM PELLET controller manual Download

EcoDesign certificate

The boiler complies with the requirements of the EcoDesign standard (Eco Design) – 50 Download
The boiler complies with the requirements of the EcoDesign standard (Eco Design) – 75-150 – 10.2023 Download
The boiler complies with the requirements of the EcoDesign standard (Eco Design) – 70-150 – 11.2020 Download

Energy label

A + energy class – 50kW Download
A + energy class – 75kW Download
A + energy class – 100kW Download
A + energy class – 150kW Download

Product sheet in accordance with EU regulation 2015/1187

According to EU Regulation 2015/1187 supplementing Directive 2009/125 / EC of the European Parliament and of the Council Download

Product sheet in accordance with EU regulation 2015/1189

According to EU Regulation 2015/1189 supplementing Directive 2009/125 / EC of the European Parliament and of the Council – 50kW Download
According to EU Regulation 2015/1189 supplementing Directive 2009/125 / EC of the European Parliament and of the Council – 75kW Download
According to EU Regulation 2015/1189 supplementing Directive 2009/125 / EC of the European Parliament and of the Council – 100kW Download
According to EU Regulation 2015/1189 supplementing Directive 2009/125 / EC of the European Parliament and of the Council – 150kW Download

Foreign sales

Do you have a question about your future central heating boiler?

Paweł Czepiel

Export manager
Language: Russian, English
Monday-Friday (7:00 a.m. – 3:00 p.m.)

Phone:

+48 663 45 32 22
+48 85 711 94 54 ext. 17

E-mail:

p.czepiel@metalfach.com.pl

METAL-FACH Technika Grzewcza Sp. z o.o. reserves the right to introduce changes to the technical parameters, equipment and specifications of the offered goods without prior notice.

General contact:

Opening hours:

  • Mon.-Fri. 7:00a.m.-3:00p.m.
  • Phone: +48 85 711 94 54 int. 17
  • E-mail: p.czepiel@metalfach.com.pl

General contact:

Service contact:

Opening hours:

  • Mon.-Fri. 7:00a.m.–3:00 p.m.
  • Phone: +48 85 711 94 54 int. 17
  • E-mail: p.czepiel@metalfach.com.pl

Address data:

METAL-FACH Technika Grzewcza
Sp. z o.o.

  • st. Sikorskiego 66, 16-100 Sokółka, Poland
  • NIP: 545-182-60-12
  • REGON: 523566030

How to get: