BOILER
SE MAX II
Essential Information
Key benefits
Heat exchanger
Effective design for quick cleaning of the exchanger from the front. The design of the boiler exchanger ensures high heat removal from the furnace.
Flue outlet
The structure of the boiler has been designed in such a way that the flue outlet is at the rear. The use of such a solution in a central heating boiler allows the flue to be directly led out to the chimney.
Scaffolding lever
Secondary air damper
Blower fan
Effectively supports the natural exhaust gas flow in the boiler. Additionally, it prevents smoke from escaping from the boiler to the boiler room. It also requires a driver to be installed.
Draft regulator
Depending on the temperature of the medium, it controls the flap regulating the air supply to the boiler combustion chamber.
Boiler control
Simple boiler control
Adjust the boiler operation and room temperature to your individual needs. The DK SYSTEM-420 controller is programmed in such a way as to automate partially the processes related to heating your home. The owner specifies the temperature he wants to have in the room, and the controller will optimize combustion in this respect.
Key features:
Manual firing up
Manual ignition and fuel loading
We can load firewood or coal into the combustion chamber. Wood, unlike coal, properly seasoned is an ecological fuel that meets all standards. It is completely natural, as a result of combustion, biodegradable ash is produced. By burning properly seasoned wood, we produce a small amount of harmful compounds into the atmosphere.
Technical data of the boiler
PARAMETERS | UNIT S.I. | SE MAX II 15 |
Nominal thermal power | [kW] | 15 |
Boiler power range | [kW] | 15 |
Heatable surface* | [m2] | 150 |
Heating area | [m2] | 0,85 |
Water capacity | [L] | 30 |
Maximum working pressure | [bar] | 1,5 |
Maximum working temperature | [°C] | 80 |
Test pressure | [bar] | 4 |
Fuel | [-] | wood, coal |
Chimney draft required | [Pa] | – |
Boiler weight | [kg] | 160 |
* A new building with very good thermal insulation was adopted for the calculations.
PARAMETERS | UNIT S.I. | SE MAX II 20 |
Nominal thermal power | [kW] | 20 |
Boiler power range | [kW] | 20 |
Heatable surface* | [m2] | 150-200 |
Heating area | [m2] | 1,15 |
Water capacity | [L] | 41 |
Maximum working pressure | [bar] | 3 |
Maximum working temperature | [°C] | 80 |
Test pressure | [bar] | 4 |
Fuel | [-] | wood, coal |
Chimney draft required | [Pa] | – |
Boiler weight | [kg] | 198 |
* A new building with very good thermal insulation was adopted for the calculations.
PARAMETERS | UNIT S.I. | SE MAX II 25 |
Nominal thermal power | [kW] | 25 |
Boiler power range | [kW] | 25 |
Heatable surface* | [m2] | 200-250 |
Heating area | [m2] | 1,56 |
Water capacity | [L] | 56 |
Maximum working pressure | [bar] | 1,5 |
Maximum working temperature | [°C] | 80 |
Test pressure | [bar] | 4 |
Fuel | [-] | wood, coal |
Chimney draft required | [Pa] | – |
Boiler weight | [kg] | 260 |
* A new building with very good thermal insulation was adopted for the calculations.
PARAMETERS | UNIT S.I. | SE MAX II 30 |
Nominal thermal power | [kW] | 30 |
Boiler power range | [kW] | 30 |
Heatable surface* | [m2] | 250-300 |
Heating area | [m2] | 2,19 |
Water capacity | [L] | 71 |
Maximum working pressure | [bar] | 1,5 |
Maximum working temperature | [°C] | 80 |
Test pressure | [bar] | 4 |
Fuel | [-] | wood, coal |
Chimney draft required | [Pa] | – |
Boiler weight | [kg] | 330 |
* A new building with very good thermal insulation was adopted for the calculations.
PARAMETERS | UNIT S.I. | SE MAX II 35 |
Nominal thermal power | [kW] | 35 |
Boiler power range | [kW] | 35 |
Heatable surface* | [m2] | 300-350 |
Heating area | [m2] | 2,27 |
Water capacity | [L] | 87 |
Maximum working pressure | [bar] | 1,5 |
Maximum working temperature | [°C] | 80 |
Test pressure | [bar] | 4 |
Fuel | [-] | wood, coal |
Chimney draft required | [Pa] | – |
Boiler weight | [kg] | 350 |
* A new building with very good thermal insulation was adopted for the calculations.
PARAMETERS | UNIT S.I. | SE MAX II 40 |
Nominal thermal power | [kW] | 40 |
Boiler power range | [kW] | 40 |
Heatable surface* | [m2] | 350-400 |
Heating area | [m2] | 2,48 |
Water capacity | [L] | 93 |
Maximum working pressure | [bar] | 1,5 |
Maximum working temperature | [°C] | 80 |
Test pressure | [bar] | 4 |
Fuel | [-] | wood, coal |
Chimney draft required | [Pa] | – |
Boiler weight | [kg] | 370 |
* A new building with very good thermal insulation was adopted for the calculations.
PARAMETERS | UNIT S.I. | SE MAX II 50 |
Nominal thermal power | [kW] | 50 |
Boiler power range | [kW] | 50 |
Heatable surface* | [m2] | 400-500 |
Heating area | [m2] | 2,7 |
Water capacity | [L] | 111 |
Maximum working pressure | [bar] | 1,5 |
Maximum working temperature | [°C] | 80 |
Test pressure | [bar] | 4 |
Fuel | [-] | wood, coal |
Chimney draft required | [Pa] | – |
Boiler weight | [kg] | 395 |
* A new building with very good thermal insulation was adopted for the calculations.
Boiler dimensions
DIMENSIONS | UNIT S.I. | SE MAX II 15 |
A | [mm] | 436 |
B1 | [mm] | – |
B2 | [mm] | – |
C1 | [mm] | 962 |
C2 | [mm] | – |
D1 | [mm] | 726 |
D2 | [mm] | 561 |
E | [mm] | – |
F1 | [mm] | 770 |
F2 | [mm] | 186 |
F3 | [mm] | 383 |
F4 | [mm] | 169 |
G1 | [mm] | 160 |
G2 | [cal] | 1 1/2 |
G3 | [cal] | 1 1/2 |
G4 | [cal] | 3/4 |
H | [mm] | 30 |
DIMENSIONS | UNIT S.I. | SE MAX II 20 |
A | [mm] | 436 |
B1 | [mm] | – |
B2 | [mm] | – |
C1 | [mm] | 1122 |
C2 | [mm] | – |
D1 | [mm] | 777 |
D2 | [mm] | 613 |
E | [mm] | – |
F1 | [mm] | 914 |
F2 | [mm] | 190 |
F3 | [mm] | 435 |
F4 | [mm] | 173 |
G1 | [mm] | 160 |
G2 | [cal] | 1 1/2 |
G3 | [cal] | 1 1/2 |
G4 | [cal] | 3/4 |
H | [mm] | 30 |
DIMENSIONS | UNIT S.I. | SE MAX II 25 |
A | [mm] | 450 |
B1 | [mm] | – |
B2 | [mm] | – |
C1 | [mm] | 1201 |
C2 | [mm] | – |
D1 | [mm] | 921 |
D2 | [mm] | 695 |
E | [mm] | – |
F1 | [mm] | 1035 |
F2 | [mm] | 253 |
F3 | [mm] | 547 |
F4 | [mm] | 241 |
G1 | [mm] | 180 |
G2 | [cal] | 1 1/2 |
G3 | [cal] | 1 1/2 |
G4 | [cal] | 3/4 |
H | [mm] | 30 |
DIMENSIONS | UNIT S.I. | SE MAX II 30 |
A | [mm] | 510 |
B1 | [mm] | – |
B2 | [mm] | – |
C1 | [mm] | 1256 |
C2 | [mm] | – |
D1 | [mm] | 1029 |
D2 | [mm] | 804 |
E | [mm] | – |
F1 | [mm] | 1090 |
F2 | [mm] | 253 |
F3 | [mm] | 671 |
F4 | [mm] | 241 |
G1 | [mm] | 180 |
G2 | [cal] | 1 1/2 |
G3 | [cal] | 1 1/2 |
G4 | [cal] | 3/4 |
H | [mm] | 30 |
DIMENSIONS | UNIT S.I. | SE MAX II 35 |
A | [mm] | 530 |
B1 | [mm] | – |
B2 | [mm] | – |
C1 | [mm] | 1256 |
C2 | [mm] | – |
D1 | [mm] | 1029 |
D2 | [mm] | 804 |
E | [mm] | – |
F1 | [mm] | 1090 |
F2 | [mm] | 253 |
F3 | [mm] | 671 |
F4 | [mm] | 241 |
G1 | [mm] | 180 |
G2 | [cal] | 1 1/2 |
G3 | [cal] | 1 1/2 |
G4 | [cal] | 3/4 |
H | [mm] | 30 |
DIMENSIONS | UNIT S.I. | SE MAX II 40 |
A | [mm] | 580 |
B1 | [mm] | – |
B2 | [mm] | – |
C1 | [mm] | 1256 |
C2 | [mm] | – |
D1 | [mm] | 1029 |
D2 | [mm] | 804 |
E | [mm] | – |
F1 | [mm] | 1090 |
F2 | [mm] | 253 |
F3 | [mm] | 671 |
F4 | [mm] | 241 |
G1 | [mm] | 180 |
G2 | [cal] | 1 1/2 |
G3 | [cal] | 1 1/2 |
G4 | [cal] | 3/4 |
H | [mm] | 30 |
DIMENSIONS | UNIT S.I. | SE MAX II 50 |
A | [mm] | 630 |
B1 | [mm] | – |
B2 | [mm] | – |
C1 | [mm] | 1256 |
C2 | [mm] | – |
D1 | [mm] | 1029 |
D2 | [mm] | 804 |
E | [mm] | – |
F1 | [mm] | 1090 |
F2 | [mm] | 253 |
F3 | [mm] | 671 |
F4 | [mm] | 241 |
G1 | [mm] | 180 |
G2 | [cal] | 1 1/2 |
G3 | [cal] | 1 1/2 |
G4 | [cal] | 3/4 |
H | [mm] | 30 |
Boiler documentation
Foreign sales
Paweł Czepiel
Export manager
Language: Russian, English
Monday-Friday (7:00 a.m. – 3:00 p.m.)
Phone:
+48 663 45 32 22
+48 85 711 94 54 ext. 17
E-mail:
p.czepiel@metalfach.com.pl
General contact:
Opening hours:
- Mon.-Fri. 7:00a.m.-3:00p.m.
- Phone: +48 85 711 94 54 int. 17
- E-mail: p.czepiel@metalfach.com.pl
General contact:
Service contact:
Opening hours:
- Mon.-Fri. 7:00a.m.–3:00 p.m.
- Phone: +48 85 711 94 54 int. 17
- E-mail: p.czepiel@metalfach.com.pl
Address data:
METAL-FACH Technika Grzewcza
Sp. z o.o.
- st. Sikorskiego 66, 16-100 Sokółka, Poland
- NIP: 545-182-60-12
- REGON: 523566030