BOILER
GRAND CARBON
Essential Information
Key benefits
Heat exchanger
Effective structure adapted to automatic cleaning of the exchanger. The design of the boiler exchanger ensures high heat removal from the furnace.
Flue outlet
The structure of the boiler has been designed so that the outlet of the flue is at the rear. The applied design of the boiler body allows the flue to be directly led out to the chimney.
Limit switch
Exhaust fan
The exhaust fan effectively supports the natural flue gas draft in the boiler.
Steel screens
Automatic feeder
Swirlers
Swirlers installed in convection ducts, connected with the automatic cleaning system, effectively reduce the speed of exhaust gas outlet. Thanks to systematic cleaning, the boiler maintains a constant high heat consumption through the water jacket. The use of automatic cleaning of convection channels contributes to the reduction of fuel consumption.
Boiler control
Key features:
Standard equipment:
Control the work, monitor, compare statistics thanks to the connection of the boiler controller with the internet module. Gain access to boiler control from a mobile phone, tablet or computer. The internet module is not only a remote control, it also records and registers the course of heating the house. Thanks to the ecoNET internet module (wired, wi-fi) you can gain control over your expenses and nothing will surprise you anymore!
Optional equipment:
Eco-pea coal burner
Ekoenergia II cast iron burner – for eco-pea coal
Cast iron boiler carburizing system with manual firing up of the furnace. The eco pea burner and its components in contact with high temperature are made of cast iron. Thanks to the use of this material in the construction of the burner, these elements are more resistant to corrosion than ordinary steel, even if we use moist fuel. Cast iron elements of the burner also reduce the noise of the feeder operation. The burner and the feeding screw are made of gray ductile cast iron, resistant mainly to abrasion and high temperature. A burner constructed in this way will work reliably for many years.
Key features:
Ecological fuel from the depths of the earth. Eco pea fuel is produced on the basis of hard coal. The prefix “eco” means that it meets the stricter gas emission standards. Eco-pea fuel has a low sulfur content, a small amount of ash and low humidity. While burning, it produces much less harmful compounds than ordinary coal.
The screw feeder doses fuel precisely, is resistant to abrasion, corrosion and high temperature.
Prevents damage to the gearmotor. When there is an element in the feeder that the auger will not be able to push out, the pin will break, which will protect the boiler against serious damage to the feeding system.
Technical data of the boiler
PARAMETERS | UNIT S.I. | GRAND CARBON 50 |
Nominal thermal power | [kW] | 50 |
Boiler power range | [kW] | 15-50 |
Heatable surface* | [m2] | 225-750 |
Water capacity | [L] | 170 |
Maximum working pressure | [bar] | 3 |
Maximum working temperature | [°C] | 80 |
Test pressure | [bar] | 4,5 |
Fuel tank capacity | [L] | 460 |
Fuel tank capacity | [kg] | 336 |
Fuel | [-] | eco-pea coal Φ0-32mm |
Electrical connection | [-] | 2A; ~230V; 50Hz |
Electric power consumption | [W] | 440 |
Temperature controller setting range | [°C] | 60-80 (every 1°C) |
Chimney draft required | [Pa] | 17 |
Boiler weight | [kg] | 910 |
* A new building with very good thermal insulation was adopted for the calculations.
PARAMETERS | UNIT S.I. | GRAND CARBON 75 |
Nominal thermal power | [kW] | 75 |
Boiler power range | [kW] | 22,5-75 |
Heatable surface* | [m2] | 337,5-1125 |
Water capacity | [L] | 225 |
Maximum working pressure | [bar] | 3 |
Maximum working temperature | [°C] | 80 |
Test pressure | [bar] | 4,5 |
Fuel tank capacity | [L] | 645 |
Fuel tank capacity | [kg] | 472 |
Fuel | [-] | eco-pea coal Φ0-32mm |
Electrical connection | [-] | 3A; ~230V; 50Hz |
Electric power consumption | [W] | 500 |
Temperature controller setting range | [°C] | 60-80 (every 1°C) |
Chimney draft required | [Pa] | 27 |
Boiler weight | [kg] | 1100 |
* A new building with very good thermal insulation was adopted for the calculations.
Certificates, class, boiler emission
PARAMETERS | UNIT S.I. | GRAND CARBON 50 |
Ecodesign | [-] | Yes |
Boiler class | [-] | 5 |
Energy class | [-] | B |
Seasonal particulate emissions | [mg/m3] | 26 |
Efficiency for nominal power | [%] | 90,5 |
Nominal emissivity of the particulate matter | [mg/m3] | 29 |
Efficiency at minimum power | [%] | 90 |
Minimum emissivity of particulate matter | [mg/m3] | 25 |
PARAMETERS | UNIT S.I. | GRAND CARBON 75 |
Ecodesign | [-] | Yes |
Boiler class | [-] | 5 |
Energy class | [-] | B |
Seasonal particulate emissions | [mg/m3] | 28 |
Efficiency for nominal power | [%] | 90 |
Nominal emissivity of the particulate matter | [mg/m3] | 29 |
Efficiency at minimum power | [%] | 90,6 |
Minimum emissivity of particulate matter | [mg/m3] | 20 |
Boiler dimensions
DIMENSION | UNIT S.I. | GRAND CARBON 50 |
A | [mm] | 1560 |
B1 | [mm] | 800 |
B2 | [mm] | 747 |
C1 | [mm] | 1400 |
C2 | [mm] | – |
D1 | [mm] | 1480 |
D2 | [mm] | 1115 |
E | [mm] | 1190 |
F1 | [mm] | 885 |
F2 | [mm] | 860 |
F3 | [mm] | 480 |
F4 | [mm] | 120 |
G1 | [mm] | 180 |
G2 | [cal] | 1 1/2 |
G3 | [cal] | 1 1/2 |
G4 | [cal] | 3/4 |
H | [mm] | 30 |
DIMENSION | UNIT S.I. | GRAND CARBON 75 |
A | [mm] | 1630 |
B1 | [mm] | 860 |
B2 | [mm] | 765 |
C1 | [mm] | 1535 |
C2 | [mm] | – |
D1 | [mm] | 1860 |
D2 | [mm] | 1465 |
E | [mm] | 1100 |
F1 | [mm] | 1065 |
F2 | [mm] | 950 |
F3 | [mm] | 625 |
F4 | [mm] | 80 |
G1 | [mm] | 180 |
G2 | [cal] | 1 1/2 |
G3 | [cal] | 1 1/2 |
G4 | [cal] | 3/4 |
H | [mm] | 30 |
Boiler documentation
DTR instruction
Technical and operational documentation for the GRAND CARBON boiler | Download |
Driver manual
PLATINUM driver manual | Download |
EcoDesign certificate
The boiler complies with the requirements of the EcoDesign standard (EkoProjekt) | Download |
Energy label
A + energy class | Download |
Product sheet in accordance with EU regulation 2015/1187
According to the EU Regulation 2015/1187 supplementing Directive 2009/125 / EC of the European Parliament and of the Council | Download |
Product sheet in accordance with EU regulation 2015/1189
Compliant with the EU Commission Regulation 2015/1189 of April 28, 2015. | Download |
Foreign sales
Paweł Czepiel
Export manager
Language: Russian, English
Monday-Friday (7:00 a.m. – 3:00 p.m.)
Phone:
+48 663 45 32 22
+48 85 711 94 54 ext. 17
E-mail:
p.czepiel@metalfach.com.pl
General contact:
Opening hours:
- Mon.-Fri. 7:00a.m.-3:00p.m.
- Phone: +48 85 711 94 54 int. 17
- E-mail: p.czepiel@metalfach.com.pl
General contact:
Service contact:
Opening hours:
- Mon.-Fri. 7:00a.m.–3:00 p.m.
- Phone: +48 85 711 94 54 int. 17
- E-mail: p.czepiel@metalfach.com.pl
Address data:
METAL-FACH Technika Grzewcza
Sp. z o.o.
- st. Sikorskiego 66, 16-100 Sokółka, Poland
- NIP: 545-182-60-12
- REGON: 523566030