BOILER
SD DUO BIO
Essential Information
Available powers: 16kW | 20kW | 28kW | 34kW
Key benefits
Heat exchanger
Effective design for quick cleaning of the exchanger from the front. The design of the boiler exchanger ensures high heat removal from the furnace.
Flue outlet
The structure of the boiler has been designed in such a way that the flue outlet is at the rear. The use of such a solution in a central heating boiler allows the flue to be directly led out to the chimney.
Limit switch
Firefighter
Exhaust steering wheel
Automatic feeder
Swirlers
Boiler control
Key features:
Optional equipment:
Control the work, monitor, compare the statistics thanks to the connection of the boiler controller with the internet module. Gain access to boiler control from a mobile phone, tablet or computer. The internet module is not only a remote control, it also records and registers the course of heating the house. Thanks to the ecoNET internet module (wired, wi-fi) you can gain control over your expenses and nothing will surprise you anymore!
Pellet burner
Gutter burner – for pellets
These are one of the most popular pellet burners on the market. The burner is equipped with an automatic ceramic pellet igniter, which allows it to be quickly ignited and extinguished. The design of the burner allows you to quickly reach a high temperature of the boiler. All functions of firing up the furnace and fuel dosage can be set in accordance with the current needs of the user.
Key features:
Ecological fuel such as pellets, also known as biomass, is produced by pressing wood waste such as sawdust or shavings. This completely natural fuel turns into biodegradable ash after burning.
Forget about manual boiler lighting. One click is enough and the automatic ceramic igniter ignites the fuel fed to the burner. Automatic igniter in conjunction with the RTC clock allows you to program the entire week of operation of the device. The device operation clock can be set separately for SUMMER and WINTER mode.
Technical data of the boiler
PARAMETERS | UNIT S.I. | SD DUO BIO 16 |
Nominal thermal power | [kW] | 16 |
Boiler power range | [kW] | 4,8-16 |
Heatable surface* | [m2] | 72-240 |
Heating area | [m2] | 2,33 |
Water capacity | [L] | 78 |
Maximum working pressure | [bar] | 3 |
Maximum working temperature | [°C] | 80 |
Test pressure | [bar] | 4,5 |
Fuel tank capacity | [L] | 300 |
Fuel tank capacity | [kg] | 180 |
Fuel | [-] | pellets Φ6-8mm |
Przyłącze elektryczne | [-] | 5A; ~230V; 50Hz |
Electric power consumption | [W] | 300 |
Temperature controller setting range | [°C] | 60-80 (every 1°C) |
Chimney draft required | [Pa] | 20 |
Boiler weight | [kg] | 460 |
* A new building with very good thermal insulation was adopted for the calculations.
PARAMETERS | UNIT S.I. | SD DUO BIO 20 |
Nominal thermal power | [kW] | 20 |
Boiler power range | [kW] | 6-20 |
Heatable surface* | [m2] | 90-300 |
Heating area | [m2] | 2,62 |
Water capacity | [L] | 84 |
Maximum working pressure | [bar] | 3 |
Maximum working temperature | [°C] | 80 |
Test pressure | [bar] | 4,5 |
Fuel tank capacity | [L] | 300 |
Fuel tank capacity | [kg] | 180 |
Fuel | [-] | pellets Φ6-8mm |
Electrical connection | [-] | 5A; ~230V; 50Hz |
Electric power consumption | [W] | 300 |
Temperature controller setting range | [°C] | 60-80 (every 1°C) |
Chimney draft required | [Pa] | 23 |
Boiler weight | [kg] | 475 |
* A new building with very good thermal insulation was adopted for the calculations.
PARAMETERS | UNIT S.I. | SD DUO BIO 28 |
Nominal thermal power | [kW] | 28 |
Boiler power range | [kW] | 8,4-28 |
Heatable surface* | [m2] | 126-420 |
Heating area | [m2] | 2,85 |
Water capacity | [L] | 90 |
Maximum working pressure | [bar] | 3 |
Maximum working temperature | [°C] | 80 |
Test pressure | [bar] | 4,5 |
Fuel tank capacity | [L] | 300 |
Fuel tank capacity | [kg] | 180 |
Fuel | [-] | pellets Φ6-8mm |
Electrical connection | [-] | 5A; ~230V; 50Hz |
Electric power consumption | [W] | 300 |
Temperature controller setting range | [°C] | 60-80 (every 1°C) |
Chimney draft required | [Pa] | 23 |
Boiler weight | [kg] | 495 |
* A new building with very good thermal insulation was adopted for the calculations.
PARAMETERS | UNIT S.I. | SD DUO BIO 34 |
Nominal thermal power | [kW] | 34 |
Boiler power range | [kW] | 10,2-34 |
Heatable surface* | [m2] | 153-510 |
Heating area | [m2] | 3,1 |
Water capacity | [L] | 100 |
Maximum working pressure | [bar] | 3 |
Maximum working temperature | [°C] | 80 |
Test pressure | [bar] | 4,5 |
Fuel tank capacity | [L] | 300 |
Fuel tank capacity | [kg] | 180 |
Fuel | [-] | pellets Φ6-8mm |
Electrical connection | [-] | 5A; ~230V; 50Hz |
Electric power consumption | [W] | 300 |
Temperature controller setting range | [°C] | 60-80 (every 1°C) |
Chimney draft required | [Pa] | 35 |
Boiler weight | [kg] | 520 |
* A new building with very good thermal insulation was adopted for the calculations.
Certificates, class, boiler emission
PARAMETERS | UNIT S.I. | SD DUO BIO 16 |
Ecodesign | [-] | Yes |
Boiler class | [-] | 5 |
Energy class | [-] | A+ |
Seasonal particulate emissions | [mg/m3] | 14 |
Efficiency for nominal power | [%] | – |
Nominal emissivity of the particulate matter | [mg/m3] | – |
Efficiency at minimum power | [%] | – |
Minimum emissivity of particulate matter | [mg/m3] | – |
PARAMETERS | UNIT S.I. | SD DUO BIO 20 |
Ecodesign | [-] | Yes |
Boiler class | [-] | 5 |
Energy class | [-] | A+ |
Seasonal particulate emissions | [mg/m3] | 26 |
Efficiency for nominal power | [%] | 90,1 |
Nominal emissivity of the particulate matter | [mg/m3] | 26 |
Efficiency at minimum power | [%] | 89,1 |
Minimum emissivity of particulate matter | [mg/m3] | 26 |
PARAMETERS | UNIT S.I. | SD DUO BIO 28 |
Ecodesign | [-] | tak |
Boiler class | [-] | 5 |
Energy class | [-] | A+ |
Seasonal particulate emissions | [mg/m3] | 14 |
Efficiency for nominal power | [%] | – |
Nominal emissivity of the particulate matter | [mg/m3] | – |
Efficiency at minimum power | [%] | – |
Minimum emissivity of particulate matter | [mg/m3] | – |
PARAMETERS | UNIT S.I. | SD DUO BIO 34 |
Ecodesign | [-] | Yes |
Boiler class | [-] | 5 |
Energy class | [-] | A+ |
Seasonal particulate emissions | [mg/m3] | 10 |
Efficiency for nominal power | [%] | 90,1 |
Nominal emissivity of the particulate matter | [mg/m3] | 13 |
Efficiency at minimum power | [%] | 90,7 |
Minimum emissivity of particulate matter | [mg/m3] | 9 |
Boiler dimensions
DIMENSION | UNIT S.I. | SD DUO BIO 16 |
A | [mm] | 1245 |
B1 | [mm] | 541 |
B2 | [mm] | 680 |
C1 | [mm] | 1665 |
C2 | [mm] | 1635 |
D1 | [mm] | 830 |
D2 | [mm] | 653 |
E | [mm] | 595 |
F1 | [mm] | 1400 |
F2 | [mm] | 244 |
F3 | [mm] | 144 |
F4 | [mm] | 442 |
G1 | [mm] | 180 |
G2 | [cal] | 1 1/2 |
G3 | [cal] | 1 1/2 |
G4 | [cal] | 3/4 |
H | [mm] | 30 |
DIMENSION | UNIT S.I. | SD DUO BIO 20 |
A | [mm] | 1245 |
B1 | [mm] | 541 |
B2 | [mm] | 680 |
C1 | [mm] | 1665 |
C2 | [mm] | 1635 |
D1 | [mm] | 880 |
D2 | [mm] | 703 |
E | [mm] | 595 |
F1 | [mm] | 1400 |
F2 | [mm] | 244 |
F3 | [mm] | 144 |
F4 | [mm] | 487 |
G1 | [mm] | 180 |
G2 | [cal] | 1 1/2 |
G3 | [cal] | 1 1/2 |
G4 | [cal] | 3/4 |
H | [mm] | 30 |
DIMENSION | UNIT S.I. | SD DUO BIO 28 |
A | [mm] | 1245 |
B1 | [mm] | 541 |
B2 | [mm] | 680 |
C1 | [mm] | 1665 |
C2 | [mm] | 1635 |
D1 | [mm] | 930 |
D2 | [mm] | 753 |
E | [mm] | 595 |
F1 | [mm] | 1400 |
F2 | [mm] | 244 |
F3 | [mm] | 144 |
F4 | [mm] | 537 |
G1 | [mm] | 180 |
G2 | [cal] | 1 1/2 |
G3 | [cal] | 1 1/2 |
G4 | [cal] | 3/4 |
H | [mm] | 30 |
DIMENSION | UNIT S.I. | SD DUO BIO 34 |
A | [mm] | 1300 |
B1 | [mm] | 591 |
B2 | [mm] | 680 |
C1 | [mm] | 1665 |
C2 | [mm] | 1635 |
D1 | [mm] | 930 |
D2 | [mm] | 753 |
E | [mm] | 595 |
F1 | [mm] | 1400 |
F2 | [mm] | 244 |
F3 | [mm] | 144 |
F4 | [mm] | 537 |
G1 | [mm] | 200 |
G2 | [cal] | 1 1/2 |
G3 | [cal] | 1 1/2 |
G4 | [cal] | 3/4 |
H | [mm] | 30 |
Boiler documentation
DTR instruction
Technical and operational documentation for the SD DUO BIO boiler | Download |
Driver manual
PLATIUM PELLET controller manual | Download |
EcoDesign certificate
Energy label
A + energy class | Download |
Product sheet in accordance with EU regulation 2015/1187
According to EU Regulation 2015/1187 supplementing Directive 2009/125 / EC of the European Parliament and of the Council | Download |
Product sheet in accordance with EU regulation 2015/1189
Compliant with the EU Commission Regulation 2015/1189 of April 28, 2015 | Download |
Foreign sales
Paweł Czepiel
Export manager
Language: Russian, English
Monday-Friday (7:00 a.m. – 3:00 p.m.)
Phone:
+48 663 45 32 22
+48 85 711 94 54 ext. 17
E-mail:
p.czepiel@metalfach.com.pl
General contact:
Opening hours:
- Mon.-Fri. 7:00a.m.-3:00p.m.
- Phone: +48 85 711 94 54 int. 17
- E-mail: p.czepiel@metalfach.com.pl
General contact:
Service contact:
Opening hours:
- Mon.-Fri. 7:00a.m.–3:00 p.m.
- Phone: +48 85 711 94 54 int. 17
- E-mail: p.czepiel@metalfach.com.pl
Address data:
METAL-FACH Technika Grzewcza
Sp. z o.o.
- st. Sikorskiego 66, 16-100 Sokółka, Poland
- NIP: 545-182-60-12
- REGON: 523566030