FIREPLACE
TYMON
Essential Information
Key benefits
Heat exchanger
Effective design adapted to quick mechanical cleaning of the exchanger from the front and top. The construction of the fireplace exchanger ensures high heat reception from the fireplace.
Flue exit
The fireplace structure has been designed in such a way that the flue outlets are located at the back. The use of such a solution in the fireplace allows the flue to be discharged directly into the chimney.
Exhaust fan
Automatic feeder
Integrated storage tank
Stable heating pressure
Fireplace control
The most important features:
Room thermostat
Additional equipment:
Pellet burner
Pellet burner
The burner is equipped with an automatic ceramic pellet igniter, which ensures quick ignition of the fireplace. The design of the burner allows you to quickly reach a high temperature in the fireplace. Fuel dosage can be set according to the user’s current needs.
The most important features:
Ecological fuel such as pellets, also called biomass, is produced by compressing wood waste such as sawdust or shavings. This fully natural fuel turns into biodegradable ash after burning.
Forget about lighting the fireplace manually. Just one click and the automatic ceramic igniter will ignite the fuel fed to the burner.
The burner should be cleaned manually and regularly to remove ash. This prevents the combustion chamber from becoming clogged with ash and also allows the burner to remain in excellent working order.
Technical data of the fireplace
PARAMETERS | UNIT S.I. | TYMON 10 |
Nominal thermal power | [kW] | 10 |
Fireplace power range | [kW] | 3-10 |
Heatable surface* | [m2] | 45-150 |
Water capacity | [L] | 17 |
Maximum working pressure | [bar] | 3 |
Maximum working temperature | [°C] | 80 |
Test pressure | [bar] | 4,5 |
Fuel tank capacity | [L] | 25 |
Fuel tank capacity | [kg] | 15 |
Fuel | [-] | pellets Φ6mm |
Electrical connection | [-] | 2A; ~230V; 50Hz |
Electric power consumption | [W] | 130 |
Temperature controller setting range | [°C] | 60-80 (every 1°C) |
Chimney draft required | [Pa] | 12 |
Weight | [kg] | 130 |
* A new building with very good thermal insulation was adopted for the calculations.
Certificates, class, emissivity of the fireplace
PARAMETERS | UNIT S.I. | TYMON 10 |
Ecodesign | [-] | Yes |
Fireplace class | [-] | 5 |
Energy class | [-] | A+ |
Seasonal particulate emissions | [mg/m3] | 25 |
Efficiency for nominal power | [%] | 90,2 |
Nominal emissivity of the particulate matter | [mg/m3] | 13,0 |
Efficiency at minimum power | [%] | 94,0 |
Minimum emissivity of particulate matter | [mg/m3] | 13,0 |
Fireplace dimensions
DIMENSION | UNIT S.I. | TYMON 10 |
A | [mm] | 520 |
B1 | [mm] | 470 |
B2 | [mm] | – |
C1 | [mm] | 1005 |
C2 | [mm] | – |
D1 | [mm] | 520 |
D2 | [mm] | – |
E | [mm] | – |
F1 | [mm] | 214,1 |
F2 | [mm] | 332,5 |
F3 | [mm] | – |
F4 | [mm] | – |
G1 | [mm] | 80 |
G2 | [mm] | 50 |
G3 | [cal] | 3/4 |
G4 | [cal] | – |
H | [mm] | 30 |
Fireplace documentation
DTR instruction
Technical and operational documentation | Download |
Driver manual
Controller manual | Download |
EcoDesign certificate
The fireplace complies with the requirements of the EcoDesign standard | Download |
Energy label
A + energy class | Download |
Product sheet in accordance with EU regulation 2015/1187
According to EU Regulation 2015/1187 supplementing Directive 2009/125 / EC of the European Parliament and of the Council | Download |
Product sheet in accordance with EU regulation 2015/1189
Compliant with the EU Commission Regulation 2015/1189 of April 28, 2015. | Download |
Foreign sales
Paweł Czepiel
Export manager
Language: Russian, English
Monday-Friday (7:00 a.m. - 3:00 p.m.)
Phone:
+48 663 45 32 22
+48 85 711 94 54 ext. 17
E-mail:
p.czepiel@metalfach.com.pl
METAL-FACH Technika Grzewcza Sp. z o.o. reserves the right to introduce changes to the technical parameters, equipment and specifications of the offered goods without prior notice.
General contact:
Opening hours:
- Mon.-Fri. 7:00a.m.-3:00p.m.
- Phone: +48 85 711 94 54 int. 17
- E-mail: p.czepiel@metalfach.com.pl
General contact:
Service contact:
Opening hours:
- Mon.-Fri. 7:00a.m.–3:00 p.m.
- Phone: +48 85 711 94 54 int. 17
- E-mail: p.czepiel@metalfach.com.pl
Address data:
METAL-FACH Technika Grzewcza
Sp. z o.o.
- st. Sikorskiego 66, 16-100 Sokółka, Poland
- NIP: 545-182-60-12
- REGON: 523566030