BOILER
SMART EKO
The most important information
The most important advantages
Heat exchanger
Effective design adapted for quick cleaning of the exchanger from the front. The construction of the boiler exchanger ensures high heat removal from the furnace.
Flue exit
The boiler structure has been designed so that the flue outlet is located at the top. The design solution of the boiler body allows the boiler to be pushed almost to the wall.
Limit switch
Highly efficient combustion chamber
Automatic feeder
Turbulators
Boiler control
Key features:
Optional equipment:
Burner for eco-pea coal
Cast iron burner Ekoenergia II – for eco-pea coal
Cast-iron carburizing system for the boiler with manual firing up of the furnace. The eco pea burner and its components in contact with high temperature are made of cast iron. Thanks to the use of this material for the construction of the burner, these elements are more resistant to corrosion than ordinary steel, even if we use moist fuel. The cast-iron elements of the burner also reduce the noise of the feeder operation. The burner and the feeding screw are made of ductile cast iron, resistant primarily to abrasion and high temperature. A burner constructed in this way will work reliably for many years.
Key features:
Ecological fuel from the depths of the earth. Eco pea fuel is produced on the basis of hard coal. The prefix “eco” means that it meets the stricter gas emission standards. The eco-pea fuel has a negligible sulfur content, a small amount of ash and low humidity. When burning, it produces much less harmful compounds than ordinary coal.
The screw feeder precisely doses the fuel, is resistant to abrasion, corrosion and high temperature.
Prevents damage to the gear motor. When there is an element in the feeder that the screw will not be able to push out, the cotter pin will break, which will protect the boiler against more serious damage to the feeding system.
Boiler technical data
PARAMETERS | S.I. UNIT | SMART EKO 12 |
Nominal heat output | [kW] | 12 |
Boiler power range | [kW] | 3,6-12 |
Area that can be heated* | [m2] | 54-180 |
Water capacity | [L] | 48 |
Maximum working pressure | [bar] | 3 |
Maximum operating temperature | [°C] | 80 |
Test pressure | [bar] | 4,5 |
Fuel tank capacity | [L] | 200 |
Fuel tank capacity | [kg] | 146 |
Fuel | [-] | eco-pea coal Φ0-32mm |
Electrical connection | [-] | 5A; ~230V; 50Hz |
Electric power consumption | [W] | 350 |
Temperature controller setting range | [°C] | 60-80 (every 1°C) |
Chimney draft required | [Pa] | 16 |
Boiler weight | [kg] | 370 |
*A new building with very good thermal insulation was used for the calculations.
PARAMETERS | S.I. UNIT | SMART EKO 15 |
Nominal heat output | [kW] | 15 |
Boiler power range | [kW] | 4,5-15 |
Area that can be heated* | [m2] | 67,5-225 |
Water capacity | [L] | 48 |
Maximum working pressure | [bar] | 3 |
Maximum operating temperature | [°C] | 80 |
Test pressure | [bar] | 4,5 |
Fuel tank capacity | [L] | 200 |
Fuel tank capacity | [kg] | 146 |
Fuel | [-] | eco-pea coal Φ0-32mm |
Electrical connection | [-] | 5A; ~230V; 50Hz |
Electric power consumption | [W] | 350 |
Temperature controller setting range | [°C] | 60-80 (every 1°C) |
Chimney draft required | [Pa] | 18 |
Boiler weight | [kg] | 380 |
*A new building with very good thermal insulation was used for the calculations.
PARAMETERS | S.I. UNIT | SMART EKO 20 |
Nominal heat output | [kW] | 20 |
Boiler power range | [kW] | 6-20 |
Area that can be heated* | [m2] | 90-300 |
Water capacity | [L] | 60 |
Maximum working pressure | [bar] | 3 |
Maximum operating temperature | [°C] | 80 |
Test pressure | [bar] | 4,5 |
Fuel tank capacity | [L] | 200 |
Fuel tank capacity | [kg] | 146 |
Fuel | [-] | eco-pea coal Φ0-32mm |
Electrical connection | [-] | 5A; ~230V; 50Hz |
Electric power consumption | [W] | 350 |
Temperature controller setting range | [°C] | 60-80 (every 1°C) |
Chimney draft required | [Pa] | 20 |
Boiler weight | [kg] | 405 |
*A new building with very good thermal insulation was used for the calculations.
PARAMETERS | S.I. UNIT | SMART EKO 25 |
Nominal heat output | [kW] | 25 |
Boiler power range | [kW] | 7,5-25 |
Area that can be heated* | [m2] | 112,5-375 |
water capacity | [L] | 71 |
Maximum working pressure | [bar] | 3 |
Maximum operating temperature | [°C] | 80 |
Test pressure | [bar] | 4,5 |
Fuel tank capacity | [L] | 200 |
Fuel tank capacity | [kg] | 146 |
Fuel | [-] | eco-pea coal Φ0-32mm |
Electrical connection | [-] | 5A; ~230V; 50Hz |
Electric power consumption | [W] | 350 |
Temperature controller setting range | [°C] | 60-80 (every 1°C) |
Chimney draft required | [Pa] | 21 |
Boiler weight | [kg] | 480 |
*A new building with very good thermal insulation was used for the calculations.
PARAMETERS | S.I. UNIT | SMART EKO 30 |
Nominal heat output | [kW] | 30 |
Boiler power range | [kW] | 9-30 |
Area that can be heated* | [m2] | 135-450 |
water capacity | [L] | 80 |
Maximum working pressure | [bar] | 3 |
Maximum operating temperature | [°C] | 80 |
Test pressure | [bar] | 4,5 |
Fuel tank capacity | [L] | 200 |
Fuel tank capacity | [kg] | 146 |
Fuel | [-] | eco-pea coal Φ0-32mm |
Electrical connection | [-] | 5A; ~230V; 50Hz |
Electric power consumption | [W] | 350 |
Temperature controller setting range | [°C] | 60-80 (every 1°C) |
Chimney draft required | [Pa] | 22 |
Boiler weight | [kg] | 522 |
*A new building with very good thermal insulation was used for the calculations.
Certificates, class, boiler emissivity
PARAMETERS | S.I. UNIT | SMART EKO 12 |
Ecodesign (Eco Design) | [-] | Yes |
Boiler class | [-] | 5 |
Energy class | [-] | B |
Seasonal emissivity of particulate matter | [mg/m3] | 26,32 |
Efficiency for nominal power | [%] | 90,96 |
Particulate nominal emissivity | [mg/m3] | 28,67 |
Efficiency for minimum power | [%] | 90,74 |
Minimum emissivity of particulates | [mg/m3] | 25,91 |
PARAMETERS | S.I. UNIT | SMART EKO 15 |
Ecodesign (Eco Design) | [-] | Yes |
Boiler class | [-] | 5 |
Energy class | [-] | B |
Seasonal emissivity of particulate matter | [mg/m3] | 23,35 |
Efficiency for nominal power | [%] | 90,69 |
Particulate nominal emissivity | [mg/m3] | 28,02 |
Efficiency for minimum power | [%] | 90,95 |
Minimum emissivity of particulates | [mg/m3] | 22,52 |
PARAMETERS | S.I. UNIT | SMART EKO 20 |
Ecodesign (Eco Design) | [-] | Yes |
Boiler class | [-] | 5 |
Energy class | [-] | B |
Seasonal emissivity of particulate matter | [mg/m3] | 22,58 |
Efficiency for nominal power | [%] | 91,0 |
Particulate nominal emissivity | [mg/m3] | 30,06 |
Efficiency for minimum power | [%] | 90,71 |
Minimum emissivity of particulates | [mg/m3] | 21,26 |
PARAMETERS | S.I. UNIT | SMART EKO 25 |
Ecodesign (Eco Design) | [-] | Yes |
Boiler class | [-] | 5 |
Energy class | [-] | B |
Seasonal emissivity of particulate matter | [mg/m3] | 23,19 |
Efficiency for nominal power | [%] | 90,94 |
Particulate nominal emissivity | [mg/m3] | 28,90 |
Efficiency for minimum power | [%] | 90,72 |
Minimum emissivity of particulates | [mg/m3] | 22,18 |
PARAMETERS | S.I. UNIT | SMART EKO 30 |
Ecodesign (Eco Design) | [-] | Yes |
Boiler class | [-] | 5 |
Energy class | [-] | B |
Seasonal emissivity of particulate matter | [mg/m3] | 23,08 |
Efficiency for nominal power | [%] | 91,02 |
Particulate nominal emissivity | [mg/m3] | 27,78 |
Efficiency for minimum power | [%] | 90,88 |
Minimum emissivity of particulates | [mg/m3] | 22,25 |
Boiler dimensions
DIMENSION | S.I. UNIT | SMART EKO 12 |
A | [mm] | 1135 |
B1 | [mm] | 535 |
B2 | [mm] | 580 |
C1 | [mm] | 1340 |
C2 | [mm] | 1240 |
D1 | [mm] | 590 |
D2 | [mm] | 560 |
E | [mm] | 610 |
F1 | [mm] | 435 |
F2 | [mm] | 1100 |
F3 | [mm] | 140 |
F4 | [mm] | 115 |
G1 | [mm] | 160 |
G2 | [cal] | 1 1/2 |
G3 | [cal] | 1 1/2 |
G4 | [cal] | 3/4 |
H | [mm] | 30 |
DIMENSION | S.I. UNIT | SMART EKO 15 |
A | [mm] | 1135 |
B1 | [mm] | 535 |
B2 | [mm] | 580 |
C1 | [mm] | 1340 |
C2 | [mm] | 1240 |
D1 | [mm] | 590 |
D2 | [mm] | 560 |
E | [mm] | 610 |
F1 | [mm] | 435 |
F2 | [mm] | 1100 |
F3 | [mm] | 140 |
F4 | [mm] | 115 |
G1 | [mm] | 160 |
G2 | [cal] | 1 1/2 |
G3 | [cal] | 1 1/2 |
G4 | [cal] | 3/4 |
H | [mm] | 30 |
DIMENSION | S.I. UNIT | SMART EKO 20 |
A | [mm] | 1135 |
B1 | [mm] | 535 |
B2 | [mm] | 580 |
C1 | [mm] | 1400 |
C2 | [mm] | 1300 |
D1 | [mm] | 660 |
D2 | [mm] | 630 |
E | [mm] | 630 |
F1 | [mm] | 505 |
F2 | [mm] | 1155 |
F3 | [mm] | 140 |
F4 | [mm] | 115 |
G1 | [mm] | 160 |
G2 | [cal] | 1 1/2 |
G3 | [cal] | 1 1/2 |
G4 | [cal] | 3/4 |
H | [mm] | 30 |
DIMENSION | S.I. UNIT | SMART EKO 25 |
A | [mm] | 1185 |
B1 | [mm] | 585 |
B2 | [mm] | 580 |
C1 | [mm] | 1400 |
C2 | [mm] | 1300 |
D1 | [mm] | 750 |
D2 | [mm] | 720 |
E | [mm] | 630 |
F1 | [mm] | 595 |
F2 | [mm] | 1155 |
F3 | [mm] | 140 |
F4 | [mm] | 115 |
G1 | [mm] | 160 |
G2 | [cal] | 1 1/2 |
G3 | [cal] | 1 1/2 |
G4 | [cal] | 3/4 |
H | [mm] | 30 |
DIMENSION | S.I. UNIT | SMART EKO 30 |
A | [mm] | 1300 |
B1 | [mm] | 585 |
B2 | [mm] | 580 |
C1 | [mm] | 1485 |
C2 | [mm] | 1395 |
D1 | [mm] | 750 |
D2 | [mm] | 720 |
E | [mm] | 630 |
F1 | [mm] | 580 |
F2 | [mm] | 1255 |
F3 | [mm] | 140 |
F4 | [mm] | 115 |
G1 | [mm] | 180 |
G2 | [cal] | 1 1/2 |
G3 | [cal] | 1 1/2 |
G4 | [cal] | 3/4 |
H | [mm] | 30 |
Boiler documentation
DTR manual
Technical and operational documentation for the SMART EKO boiler | Download |
Driver Manual
PLATINUM driver manual | Download |
EcoDesign certificate
Boiler compliant with the requirements of the EcoDesign standard (EcoDesign) | Download |
Energy label
Energy class A+ | Download |
Product fiche in accordance with EU Regulation 2015/1187
In accordance with EU Regulation 2015/1187 supplementing Directive 2009/125/EC of the European Parliament and of the Council | Download |
Product sheet according to EU Regulation 2015/1189
Compliant with the Regulation of the EU Commission 2015/1189 of April 28, 2015. | Download |
Foreign sales
Paweł Czepiel
Export manager
Language: Russian, English
Monday-Friday (7:00 a.m. – 3:00 p.m.)
Phone:
+48 663 45 32 22
+48 85 711 94 54 ext. 17
E-mail:
p.czepiel@metalfach.com.pl
Dane adresowe:
METAL-FACH Technika Grzewcza
Sp. z o.o.
- ul. Sikorskiego 66, 16-100 Sokółka, Polska
- NIP: 545-182-60-12
- REGON: 523566030
Kontakt ogólny:
Otwarte:
- Pon.-Pt. 07: 00-15:00
- Tel. +48 85 711 94 54
- E-mail: sprzedaz@metalfach.com.pl
Kontakt serwis:
- Pon.-Pt. 7:00-20:00
- Sob. 8:00-14:00
- Niedz. 10:00-14:00
- Tel. +48 85 711 94 56
- E-mail: serwis.kotly@metalfach.com.pl
Kontakt serwis:
Pompy ciepła:
- Pon.-Pt. 7:00-15:00
- Tel. +48 85 711 94 54 wew. 12
- E-mail: serwis.pompy@metalfach.com.pl
Dofinansowanie:
Social Media:
2010-2024 © Copyright METAL-FACH Technika Grzewcza Sp. z o.o. | Wszelkie prawa zastrzeżone.