BOILER
SMART BIO
The most important information
The most important advantages
Heat exchanger
Effective design adapted for quick cleaning of the exchanger from the front. The construction of the boiler exchanger ensures high heat removal from the furnace.
Flue exit
The boiler structure has been designed in such a way that the flue exits are at the top. The use of such a solution in the central heating boiler allows for direct discharge of the flue into the chimney.
Limit switch
Ceramic plates
Automatic feeder
Turbulators
Boiler control
Key features:
Additional equipment:
Control operation, monitor, compare statistics by connecting the boiler controller with the Internet module. Gain access to boiler control from a mobile phone, tablet or computer. The Internet module is not only a remote control, it is also a recording and register of the course of heating the house. Thanks to the ecoNET internet module (wired, wi-fi) you can gain control over your expenses and nothing will surprise you anymore!
Pellet burner
Gutter burner – for pellets
These are one of the most popular pellet burners on the market. The burner is equipped with an automatic ceramic pellet igniter, which allows for its quick firing and extinguishing. The design of the burner allows you to quickly reach a high temperature of the boiler. All functions of firing up the furnace and fuel dosing can be set according to the current needs of the user.
Key Features:
Ecological fuel, which is pellets, also known as biomass, is made by pressing wood waste such as sawdust or shavings. This fully natural fuel turns into biodegradable ash when burned.
Forget about manually firing up the boiler. Just one click and the automatic ceramic igniter ignites the fuel fed to the burner. The automatic igniter combined with the RTC clock allows you to program the entire working week of the device. The device operation timer can be set separately for SUMMER and WINTER modes.
Boiler technical data
PARAMETERS | S.I. UNIT | SMART BIO 15 |
Nominal heat output | [kW] | 15 |
Boiler power range | [kW] | 4,5-15 |
Area that can be heated* | [m2] | 67,5-225 |
Water capacity | [L] | 48 |
Maximum working pressure | [bar] | 3 |
Maximum operating temperature | [°C] | 80 |
Test pressure | [bar] | 4,5 |
Fuel tank capacity | [L] | 190 |
Fuel tank capacity | [kg] | 114 |
Fuel | [-] | pellets Φ6-8mm |
Electrical connection | [-] | 3A; ~230V; 50Hz |
Electric power consumption | [W] | 290 |
Temperature controller setting range | [°C] | 60-80 (every 1°C) |
Chimney draft required | [Pa] | 17 |
Boiler weight | [kg] | 335 |
*A new building with very good thermal insulation was used for the calculations.
PARAMETERS | S.I. UNIT | SMART BIO 20 |
Nominal heat output | [kW] | 20 |
Boiler power range | [kW] | 6-20 |
Area that can be heated* | [m2] | 90-300 |
Water capacity | [L] | 60 |
Maximum working pressure | [bar] | 3 |
Maximum operating temperature | [°C] | 80 |
Test pressure | [bar] | 4,5 |
Pojemność zasobnika paliwa | [L] | 200 |
Fuel tank capacity | [kg] | 120 |
Fuel | [-] | pellets Φ6-8mm |
Electrical connection | [-] | 3A; ~230V; 50Hz |
Electric power consumption | [W] | 290 |
Temperature controller setting range | [°C] | 60-80 (every 1°C) |
Chimney draft required | [Pa] | 20 |
Boiler weight | [kg] | 360 |
*A new building with very good thermal insulation was used for the calculations.
PARAMETERS | S.I. UNIT | SMART BIO 25 |
Nominal heat output | [kW] | 25 |
Boiler power range | [kW] | 7,5-25 |
Area that can be heated* | [m2] | 112,5-375 |
Water capacity | [L] | 71 |
Maximum working pressure | [bar] | 3 |
Maximum operating temperature | [°C] | 80 |
Test pressure | [bar] | 4,5 |
Fuel tank capacity | [L] | 260 |
Fuel tank capacity | [kg] | 156 |
Fuel | [-] | pellets Φ6-8mm |
Electrical connection | [-] | 3A; ~230V; 50Hz |
Electric power consumption | [W] | 290 |
Temperature controller setting range | [°C] | 60-80 (every 1°C) |
Chimney draft required | [Pa] | 20 |
Boiler weight | [kg] | 410 |
*A new building with very good thermal insulation was used for the calculations.
PARAMETERS | S.I. UNIT | SMART BIO 30 |
Nominal heat output | [kW] | 30 |
Boiler power range | [kW] | 9-30 |
Area that can be heated* | [m2] | 135-450 |
Water capacity | [L] | 80 |
Maximum working pressure | [bar] | 3 |
Maximum operating temperature | [°C] | 80 |
Test pressure | [bar] | 4,5 |
Fuel tank capacity | [L] | 260 |
Fuel tank capacity | [kg] | 156 |
Fuel | [-] | pellets Φ6-8mm |
Electrical connection | [-] | 3A; ~230V; 50Hz |
Electric power consumption | [W] | 290 |
Temperature controller setting range | [°C] | 60-80 (co 1°C) |
Chimney draft required | [Pa] | 26 |
Boiler weight | [kg] | 430 |
*A new building with very good thermal insulation was used for the calculations.
Certificates, class, boiler emissivity
PARAMETERS | S.I. UNIT | SMART BIO 15 |
Ecodesign (Eko Project) | [-] | Yes |
Boiler class | [-] | 5 |
Energy class | [-] | A+ |
Seasonal emissivity of particulate matter | [mg/m3] | 19 |
Efficiency for nominal power | [%] | 90,7 |
Particulate nominal emissivity | [mg/m3] | 20 |
Efficiency for minimum power | [%] | 89,9 |
Minimum emissivity of particulates | [mg/m3] | 12 |
PARAMETERS | S.I. UNIT | SMART BIO 20 |
Ecodesign (Eko Project) | [-] | Yes |
Boiler class | [-] | 5 |
Energy class | [-] | A+ |
Seasonal emissivity of particulate matter | [mg/m3] | 14 |
Efficiency for nominal power | [%] | 90,2 |
Particulate nominal emissivity | [mg/m3] | 10 |
Efficiency for minimum power | [%] | 90,0 |
Minimum emissivity of particulates | [mg/m3] | 15 |
PARAMETERS | S.I. UNIT | SMART BIO 25 |
Ecodesign (Eko Project) | [-] | Yes |
Boiler class | [-] | 5 |
Energy class | [-] | A+ |
Seasonal emissivity of particulate matter | [mg/m3] | 19 |
Efficiency for nominal power | [%] | 90,6 |
Particulate nominal emissivity | [mg/m3] | 15 |
Efficiency for minimum power | [%] | 90,0 |
Minimum emissivity of particulates | [mg/m3] | 20 |
PARAMETERS | S.I. UNIT | SMART BIO 30 |
Ecodesign (Eko Project) | [-] | Yes |
Boiler class | [-] | 5 |
Energy class | [-] | A+ |
Seasonal emissivity of particulate matter | [mg/m3] | 16 |
Efficiency for nominal power | [%] | 90,7 |
Particulate nominal emissivity | [mg/m3] | 15 |
Efficiency for minimum power | [%] | 90,2 |
Minimum emissivity of particulates | [mg/m3] | 16 |
Boiler dimensions
DIMENSION | S.I. UNIT | SMART BIO 15 |
A | [mm] | 1150 |
B1 | [mm] | 535 |
B2 | [mm] | 580 |
C1 | [mm] | 1340 |
C2 | [mm] | 1240 |
D1 | [mm] | 590 |
D2 | [mm] | 560 |
E | [mm] | – |
F1 | [mm] | 435 |
F1′ | [mm] | 1100 |
F2 | [mm] | 1100 |
F3 | [mm] | 140 |
F4 | [mm] | 115 |
G1 | [mm] | 160 |
G2 | [cal] | 1 1/2 |
G3 | [cal] | 1 1/2 |
G4 | [cal] | 3/4 |
H | [mm] | 30 |
DIMENSION | S.I. UNIT | SMART BIO 20 |
A | [mm] | 1135 |
B1 | [mm] | 535 |
B2 | [mm] | 580 |
C1 | [mm] | 1400 |
C2 | [mm] | 1300 |
D1 | [mm] | 660 |
D2 | [mm] | 630 |
E | [mm] | – |
F1 | [mm] | 505 |
F1′ | [mm] | 1155 |
F2 | [mm] | 1160 |
F3 | [mm] | 140 |
F4 | [mm] | 115 |
G1 | [mm] | 160 |
G2 | [cal] | 1 1/2 |
G3 | [cal] | 1 1/2 |
G4 | [cal] | 3/4 |
H | [mm] | 30 |
DIMENSION | S.I. UNIT | SMART BIO 25 |
A | [mm] | 1300 |
B1 | [mm] | 585 |
B2 | [mm] | 680 |
C1 | [mm] | 1400 |
C2 | [mm] | 1300 |
D1 | [mm] | 750 |
D2 | [mm] | 720 |
E | [mm] | – |
F1 | [mm] | 595 |
F1′ | [mm] | 1155 |
F2 | [mm] | 1160 |
F3 | [mm] | 140 |
F4 | [mm] | 115 |
G1 | [mm] | 160 |
G2 | [cal] | 1 1/2 |
G3 | [cal] | 1 1/2 |
G4 | [cal] | 3/4 |
H | [mm] | 30 |
DIMENSION | S.I. UNIT | SMART BIO 30 |
A | [mm] | 1300 |
B1 | [mm] | 585 |
B2 | [mm] | 680 |
C1 | [mm] | 1485 |
C2 | [mm] | 1395 |
D1 | [mm] | 750 |
D2 | [mm] | 720 |
E | [mm] | – |
F1 | [mm] | 580 |
F1′ | [mm] | 1190 |
F2 | [mm] | 1255 |
F3 | [mm] | 140 |
F4 | [mm] | 115 |
G1 | [mm] | 180 |
G2 | [cal] | 1 1/2 |
G3 | [cal] | 1 1/2 |
G4 | [cal] | 3/4 |
H | [mm] | 30 |
Boiler documentation
DTR manual
Technical and operational documentation for the SMART BIO boiler | Download |
Driver Manual
PLATINUM PELLET controller manual | Download |
EcoDesign certificate
Boiler compliant with the requirements of the EcoDesign standard (EcoDesign) | Download |
Energy label
Energy class A+ | Download |
Product fiche in accordance with EU Regulation 2015/1187
In accordance with EU Regulation 2015/1187 supplementing Directive 2009/125/EC of the European Parliament and of the Council | Download |
Product sheet according to EU Regulation 2015/1189
Complies with the Regulation of the EU Commission 2015/1189 of April 28, 2015 | Download |
Foreign sales
Paweł Czepiel
Export manager
Language: Russian, English
Monday-Friday (7:00 a.m. – 3:00 p.m.)
Phone:
+48 663 45 32 22
+48 85 711 94 54 ext. 17
E-mail:
p.czepiel@metalfach.com.pl
Dane adresowe:
METAL-FACH Technika Grzewcza
Sp. z o.o.
- ul. Sikorskiego 66, 16-100 Sokółka, Polska
- NIP: 545-182-60-12
- REGON: 523566030
Kontakt ogólny:
Otwarte:
- Pon.-Pt. 07: 00-15:00
- Tel. +48 85 711 94 54
- E-mail: sprzedaz@metalfach.com.pl
Kontakt serwis:
- Pon.-Pt. 7:00-20:00
- Sob. 8:00-14:00
- Niedz. 10:00-14:00
- Tel. +48 85 711 94 56
- E-mail: serwis.kotly@metalfach.com.pl
Kontakt serwis:
Pompy ciepła:
- Pon.-Pt. 7:00-15:00
- Tel. +48 85 711 94 54 wew. 12
- E-mail: serwis.pompy@metalfach.com.pl
Dofinansowanie:
Social Media:
2010-2024 © Copyright METAL-FACH Technika Grzewcza Sp. z o.o. | Wszelkie prawa zastrzeżone.