The most important information

The SEMAX BASIC DUO boiler has been designed for small boiler rooms. This device is considered a wood gasification boiler. An additional advantage of the boiler is also its hopper, which can be placed on any side, which makes it easy to adapt to small boiler rooms. The SEMAX BASIC DUO boiler qualifies as a wood gasification boiler, but it also allows pellet combustion in automatic mode. The boiler is adapted for efficient combustion of firewood, piece wood in accordance with the 303-5: 2021-09 standard, and wood pallets in accordance with the PN EN 303-5: 2021-09 standard. It is equipped with a self-cleaning burner. The pellet igniter cooperates with the RTC clock, lighting and extinguishing the boiler according to the schedule, reducing the number of activities to be performed on the boiler to almost zero. Thanks to the possibility of connecting the ecoNET300 internet module to the boiler, you can manage the boiler functions from your phone, tablet or computer.
SEMAX BASIC DUO wood gasification boiler with the option of burning pellets!
Z
Available power: 15,20kW
Z
Primary fuel: firewood, pieces
Z
Additional fuel: pellets
Z
Certificates: EcoDesign | 5th class
Z
Energy class: A+

The most important advantages

Z

Heat exchanger

Heat exchanger | horizontal convection channels | shelf and tubular
Effective design adapted for quick cleaning of the exchanger at the front. The construction of the boiler exchanger ensures high heat reception from the furnace.
Z

Flue exit

At the back of the boiler | top and side adjustment from the fan
The boiler structure has been designed in such a way that the flue outlets are located at the back. The use of such a solution in a central heating boiler allows the flue to be discharged directly into the chimney.
Z

Exhaust gas temperature sensor

Together with the controller, the sensor controls the exhaust gas temperature.
Z

Secondary and primary air intake

Air is sucked in through six holes to fully burn the fuel. The amount of secondary and primary air can be adjusted with sliders.

Air intakes must be completely closed when using a boiler with a feeder.

Z

Smoke exhaust flap

It allows for effective smoke removal from the combustion chamber, depending on the user’s needs.

The smoke exhaust flap must be completely closed when using a boiler with a feeder.

Z

Exhaust fan

Regulated high
The exhaust fan effectively supports the natural draft of exhaust gases in the boiler.

The air is regulated using an exhaust and blowing fan when using a boiler with a feeder.

Z

Automatic feeder

The PLATINUM PELLET controller, based on information received from the sensors, determines the fuel demand and dispenses the appropriate amount. The fuel combustion process itself is therefore very economical, ecological and does not require additional maintenance on the part of the user.

Boiler control

Adjust the boiler operation and temperature in the rooms to your individual needs. The PLATINUM PELLET controller is programmed in such a way as to automate all processes related to heating your home. The owner gives the temperature he wants in the apartment, and the controller will optimize combustion in this respect. By entering the advanced settings of the controller, you can personalize each parameter. It all depends on the preferences of the user and household members!

Key Features:

E
One central heating mixing circuit with a room thermostat
E
Pump (DHW, CH, additional)
E
RTC clock with weekly programmer
E
Weather control
E
Winter/Summer operating mode
E
FuzzyLogic & PID

Optional equipment:

E
ecoNET 300 internet module
Control operation, monitor, compare statistics by connecting the boiler controller with the Internet module. Gain access to boiler control from a mobile phone, tablet or computer. The Internet module is not only a remote control, it is also a recording and register of the course of heating the house. Thanks to the ecoNET internet module (wired, wi-fi) you can gain control over your expenses and nothing will surprise you anymore!
E
Lambda probe
E
Room thermostat PLATINUM TOUCH (touch, wired)
E
Room thermostat PLATINUM TOUCH x40 (analog, wireless)
E
Room thermostat PLATINUM TOUCH x80 (touch, wireless)
E
Platinum B&C module – the extension module can operate as a B or C module.
Mode B allows you to extend the functionality of the boiler with: two additional heating circuits, 2x pumps, 2x mixer, 2x universal thermostat, H output.
Mode C allows you to extend the functionality of the boiler with two additional heating circuits, 2x pumps, 2x mixer, 2x universal thermostat.

Pellet burner

Burner DW Self-cleaning – for pellets

Quick firing up of the hearth and automatic cleaning of the hearth from ashes. The burner is equipped with an automatic ceramic pellet igniter and has been designed for regular, self-cleaning of ash. The design of the burner allows you to quickly reach a high temperature of the boiler. All functions of cleaning the ash from the furnace and fuel dosing can be set according to the current needs of the user.

Key Features:

E
Fuel: pellets
Ecological fuel, which is pellets, also known as biomass, is made by pressing wood waste such as sawdust or shavings. This fully natural fuel turns into biodegradable ash when burned.
E
Ceramic pellet lighter
Forget about manually firing up the boiler. Just one click and the automatic ceramic igniter ignites the fuel fed to the burner. The automatic igniter combined with the RTC clock allows you to program the entire working week of the device. The device operation timer can be set separately for SUMMER and WINTER modes.
E
Automatic cleaning
The burner regularly cleans itself of ash, which reduces the need for manual cleaning to a minimum. The use of this technology prevents the combustion chamber from becoming clogged with ash, and also allows the burner itself to remain in excellent efficiency.

Boiler technical data

PARAMETERS S.I. UNIT SEMAX BASIC DUO
Nominal heat output [kW] 15
Boiler power range [kW] 4,5-15
Area that can be heated* [m2] 67,5-225
Water capacity [L] 71
Maximum working pressure [bar] 3
Maximum operating temperature [°C] 80
Test pressure [bar] 4,5
Fuel tank capacity [L] 230
Fuel tank capacity [kg] 138
Primary fuel [-] firewood, pieces
Additional fuel [-] pellet Φ6-8mm
Electrical connection [-] 1A; ~230V; 50Hz
Electric power consumption [W]
Temperature controller setting range [°C] 60-80 (every 1°C)
Chimney draft required [Pa] 17-23
Thermal storage tank capacity [L] 555
Boiler weight [kg] 342

*A new building with very good thermal insulation was assumed for the calculations.

PARAMETERS S.I. UNIT SEMAX BASIC DUO 20
Nominal heat output [kW] 20
Boiler power range [kW] 6-20
Area that can be heated* [m2] 90-300
Water capacity [L] 77
Maximum working pressure [bar] 3
Maximum operating temperature [°C] 80
Test pressure [bar] 4,5
Fuel tank capacity [L] 230
Fuel tank capacity [kg] 138
Primary fuel [-] firewood, pieces
Additional fuel [-] pellet Φ6-8mm
Electrical connection [-] 1A; ~230V; 50Hz
Electric power consumption [W]
Temperature controller setting range [°C] 60-80 (every 1°C)
Chimney draft required [Pa] 22
Thermal storage tank capacity [L] 780
Boiler weight [kg] 390

*A new building with very good thermal insulation was assumed for the calculations.

Certificates, class, boiler emissivity

PARAMETERS S.I. UNIT SEMAX BASIC 15
Ecodesign (Eco Project) [-] yes
Boiler class [-] 5
Energy class [-] A+
Seasonal emissivity of particulate matter [mg/m3] 20
Efficiency for nominal power [%] 90
Particulate nominal emissivity [mg/m3] 20
Efficiency for minimum power [%]
Minimum emissivity of particulates [mg/m3]
PARAMETERS S.I. UNIT SEMAX BASIC 15
Ecodesign (Eco Project) [-] yes
Boiler class [-] 5
Energy class [-] A+
Seasonal emissivity of particulate matter [mg/m3] 17
Efficiency for nominal power [%] 91,0
Particulate nominal emissivity [mg/m3] 13
Efficiency for minimum power [%] 89,0
Minimum emissivity of particulates [mg/m3] 18
PARAMETERS S.I. UNIT SEMAX BASIC 20
Ecodesign (Eco Project) [-] yes
Boiler class [-] 5
Energy class [-] A+
Seasonal emissivity of particulate matter [mg/m3] 18
Efficiency for nominal power [%] 88,7
Particulate nominal emissivity [mg/m3] 17
Efficiency for minimum power [%]
Minimum emissivity of particulates [mg/m3]
PARAMETERS S.I. UNIT SEMAX BASIC DUO 20
Ecodesign (Eco Project) [-] yes
Boiler class [-] 5
Energy class [-] A+
Seasonal emissivity of particulate matter [mg/m3] 19
Efficiency for nominal power [%] 91,0
Particulate nominal emissivity [mg/m3] 16
Efficiency for minimum power [%] 90,0
Minimum emissivity of particulates [mg/m3] 20

Boiler dimensions

DIMENSION S.I. UNIT SEMAX BASIC DUO 15
A [mm] 1135
B1 [mm] 490
B2 [mm] 605
C1 [mm] 1275
C2 [mm] 1255
D1 [mm] 1352
D2 [mm] 725
E [mm] 605
F1 [mm] 1050
F2 [mm] 713
F3 [mm] 80
F4 [mm] 448
G1 [mm] 159
G2 [cal] 3/4
G3 [cal] 1 1/2
G4 [cal] 1 1/2
H [mm] 30
X [mm] 290
Y [mm] 515
Z [mm] 345
Loading hole [mm] 290×200
DIMENSION S.I. UNIT SEMAX BASIC DUO 20
A [mm] 1135
B1 [mm] 520
B2 [mm] 605
C1 [mm] 1275
C2 [mm] 1255
D1 [mm] 1452
D2 [mm] 835
E [mm] 605
F1 [mm] 1050
F2 [mm] 713
F3 [mm] 80
F4 [mm] 455
G1 [mm] 159
G2 [cal] 3/4
G3 [cal] 1 1/2
G4 [cal] 1 1/2
H [mm] 30
X [mm] 290
Y [mm] 515
Z [mm] 445
Loading hole [mm] 290×200

Boiler documentation

Documentation will be available after 15.11.2024

Skontaktuj się z nami

Paweł Wyszołmirski

Specjalista ds. sprzedaży
Region: woj. warmińsko-mazurskie, woj. podlaskie, woj. mazowieckie, woj. lubelskie, woj. świętokrzyskie, woj. małopolskie, woj. podkarpackie
Tel.: +48 609 341 010
E-mail: p.wyszolmirski@metalfach.com.pl

Rafał Szelest

Specjalista ds. sprzedaży
Region: woj. pomorskie, woj. zachodnio-pomorskie, woj. kujawsko-pomorskie, woj. wielkopolskie, woj. lubuskie, woj. łódzkie, woj. dolnośląskie, woj. opolskie, woj. śląskie
Tel.: +48 695 056 045
E-mail: r.szelest@metalfach.com.pl

Firma METAL-FACH Technika Grzewcza Sp. z o.o. zastrzega sobie prawo wprowadzania bez uprzedzenia zmian parametrów technicznych, wyposażenia i specyfikacji oferowanych towarów. Zawarte informacje nie stanowią zapewnienia w rozumieniu art. 4 ust. 3 i 4 ustawy z dnia 27.07.2002r. o szczególnych warunkach sprzedaży konsumenckiej oraz o zmianie Kodeksu Cywilnego (dalej “Ustawa”), a także nie stanowią opisu towaru w rozumieniu art. 4 ust. 2 Ustawy. Informator nie stanowi oferty w rozumieniu art. 66 Kodeksu Cywilnego.

Dane adresowe:

METAL-FACH Technika Grzewcza
Sp. z o.o.

  • ul. Sikorskiego 66, 16-100 Sokółka, Polska
  • NIP: 545-182-60-12
  • REGON: 523566030

Kontakt ogólny:

Otwarte:

  • Pon.-Pt. 07: 00-15:00
  • Tel. +48 85 711 94 54
  • E-mail: sprzedaz@metalfach.com.pl

Kontakt serwis:

Kotły c.o.:

  • Pon.-Pt. 7:00-20:00
  • Sob. 8:00-14:00
  • Niedz. 10:00-14:00
  • Tel. +48 85 711 94 56
  • E-mail: serwis.kotly@metalfach.com.pl

Kontakt serwis:

Pompy ciepła:

  • Pon.-Pt. 7:00-15:00
  • Tel. +48 85 711 94 54 wew. 12
  • E-mail: serwis.pompy@metalfach.com.pl

2010-2024 © Copyright METAL-FACH Technika Grzewcza Sp. z o.o. | Wszelkie prawa zastrzeżone.